Kľúčové špecifikácie
: Surge protection
Color: green (RAL 6021)
Depth: 56 mm
Width: 6.2 mm
Informácie o dodávateľovi
Produkty: 0
Zvyčajne sa odosiela do 2-3 pracovných dní
Zaručená kvalita
Rýchle doručenie
Technická podpora

Technické špecifikácie

Parameter Hodnota
Surge protection
Color green (RAL 6021)
Depth 56 mm
Width 6.2 mm
Height 80 mm
Insulation Basic insulation
Application Output function
Typ produktu Solid-state relay module
Screw thread M3
Assembly note in rows with zero spacing
Mounting type DIN rail mounting
Operating mode 100% operating factor
Output circuit 2-conductor floating, 3-conductor ground-referenced
Product family DEK
Output resistor approx. 22 kΩ (for 3-conductor operation)
Article revision 22
Pollution degree 2
Stripping length 8 mm
Connection method Screw connection
Mounting position any
Tightening torque 0.5 Nm
Order information: The housing is open on one side. The appropriate cover is D-DEK 1,5 GN (2716949).
Protective circuit Reverse polarity protection
Input voltage range 207 V AC ... 253 V AC
Note on application Use of EB 80-DIK... bridges in the DEK terminal blocks: Absorption of humidity from the ambient air as well as an unfavorable tolerance between a larger number of DEK terminal blocks and the EB 80-DIK... bridge may cause (minor) expansion of the DEK housing. When the EB 80-DIK... bridges are used, therefore, it is recommended that these be disconnected after about 10 to 12 DEK terminal blocks and a wire bridge to the next DEK terminal block be inserted in their place.
Output voltage range 3 V DC ... 48 V DC
Overvoltage category III
Standards/regulations IEC 60947-5-1
Typical response time 10 ms
Typical turn-off time 20 ms
Contact switching type 1 N/O contact
Transmission frequency 3 Hz
Design of digital output electronic
Nominal input voltage UN 230 V AC
Operating voltage display Yellow LED
Conductor cross section AWG 24 ... 14
Limiting continuous current 100 mA
Test voltage (Input/output) 2.5 kV AC (Input/output)
Typical input current at UN 2.5 mA
Date of last data management 03.05.2024
Conductor cross section rigid 0.2 mm² ... 2.5 mm²
Ambient temperature (operation) -20 °C ... 60 °C
Conductor cross section flexible 0.2 mm² ... 2.5 mm²
Input voltage range in reference to UN 0.9 ... 1.1
Switching threshold "1" signal voltage ≥ 207 V
Ambient temperature (storage/transport) -20 °C ... 70 °C
Switching threshold "0" signal, voltage ≤ 92 V
Voltage drop at max. limiting continuous current ≤ 0.9 V
Switching threshold "0" signal in reference to UN ≤ 0.4
Switching threshold "1" signal in reference to UN ≥ 0.9

Popis produktu

Input solid-state relay terminal, input: 230 V AC, output: 3 - 48 V DC/ 100 mA, terminal width 6.2 mm