Čas služby: pondelok až piatok 9:00-18:00
XT 2,5 - XT 2,5 1343106 PHOENIX CONTACT Feed-through terminal, nominal voltage: 800 V, nominal current: 24 A, number ..
Na sklade Horúci produkt

XT 2,5

XT 2,5 1343106 PHOENIX CONTACT Feed-through terminal, nominal voltage: 800 V, nominal current: 24 A, number ..

$1.08 USD
9302 na sklade
Kľúčové špecifikácie
: Machine building
Depth: 35.3 mm
Width: 5.2 mm
Colour: grey
Informácie o dodávateľovi
Produkty: 0
Zvyčajne sa odosiela do 2-3 pracovných dní
Zaručená kvalita
Rýchle doručenie
Technická podpora

Technické špecifikácie

Parameter Hodnota
Machine building
Depth 35.3 mm
Width 5.2 mm
Colour grey
Height 48.6 mm
Result Approved Test
Spectrum Category 2 durability test, on the bogie
ASD Level 6.12 (m/s²)²/Hz
Lid Width 2.2 mm
Potential 1
Rotations 135
frequency f1= 5 Hz to f2= 250 Hz
Shock Type Semi-sinusoid
Peel Length 10 mm ... 12 mm
Acceleration 3.12g
Product Type Pass-through terminal
Open sidewall Yes
Number of rows 1
Rotation speed 9 r.p.m.
Surge Category Iii
Nominal Section 2.5 mm²
Nominal current 24 A
Nominal voltage 800 V
Number of poles 1
Test Directions X, Y, and Z axes
Performance Time 30 sec
Type of mounting NS 35/7.5
Depth at NS 35/15 44.3 mm
Depth at NS 35/7.5 36.8 mm
Temperature Cycles 192
Test Specification DIN EN 50155 (VDE 0115-200):2022-06
Degree of pollution 3
Field of Employment Railway industry
Insulating material PA
Rail/Fixing Surface NS 35
AWG Conductor Section (Converted according to IEC)
Duration of the crash 18 ms
Number of connections 2
Test duration per axis 5 h
Rigid conductor section 0.5 mm² ... 4 mm²
Conductor Section/Weight 0.5 mm2/0.3 kg
Heating test requirement Temperature rise ≤ 45 K
Maximum Charging Current 27 A (with rigid 4 mm² cable cross-section)
Insulating material group I
Flexible conductor section 0.75 mm² ... 4 mm²
Test Voltage Nominal Value 9.8 kV
Ambient Temperature (Drive) -5 °C ... 70 °C
Flexible Wire Section [AWG] 18 ... 12 (Converted according to IEC)
Standard-compliant connection IEC 60947-7-1
Ambient Temperature (Mounting) -5 °C ... 70 °C
Dimensioning Transient Voltage 8 kV
Number of connections per floor 2
Number of collisions per steering 3
Flammability class according to UL 94 V0
NFPA 130 Flue Gas Toxicity (SMP 800C) approved
Static use of cold insulating material -60 °C
Ambient Temperature (Storage/Transport) -25 °C ... 60 °C (for a short time, no more than 24 hours, -60 °C to +70 °C)
Short-term permissible current 2.5 mm² 0.3 kA
Permissible air humidity (storage/transport) 30 % ... 70 %
Flammability of NFPA 130 Surfaces (ASTM E 162) approved
Maximum Dissipated Power with Nominal Condition 0.77 W
Flexible cable section (toe cap with plastic sleeve) 0.5 mm² ... 2.5 mm²
Fire protection for rail vehicles (DIN EN 45545-2) R22 HL 1 - HL 3
Fire protection for rail vehicles (DIN EN 45545-2) R23 HL 1 - HL 3
Fire protection for rail vehicles (DIN EN 45545-2) R24 HL 1 - HL 3
Fire protection for rail vehicles (DIN EN 45545-2) R26 HL 1 - HL 3
Flexible cable section (toe cap without plastic sleeve) 0.5 mm² ... 2.5 mm²
NFPA 130 Specific Optical Flue Gas Density (ASTM E 662) approved
Relative Insulating Material Temperature Index (Elec., UL 746 B) 130 °C

Popis produktu

More details
Kľúčové vlastnosti
  • Priemyselná kvalita
  • V súlade s RoHS
  • Certifikácia CE
  • 1-ročná záruka

Dokumenty k produktu

Dátový list

Technické špecifikácie a údaje o výkone

Používateľská príručka

Návod na inštaláciu a obsluhu