Kľúčové špecifikácie
: Machine building
Depth: 35.3 mm
Width: 5.2 mm
Colour: Green
Informácie o dodávateľovi
Produkty: 0
Zvyčajne sa odosiela do 2-3 pracovných dní
Zaručená kvalita
Rýchle doručenie
Technická podpora

Technické špecifikácie

Parameter Hodnota
Machine building
Depth 35.3 mm
Width 5.2 mm
Colour Green
Height 48.6 mm
Result Approved Test
Spectrum Category 2 durability test, on the bogie
ASD Level 6.12 (m/s²)²/Hz
Lid Width 2.2 mm
frequency f1= 5 Hz to f2= 250 Hz
Shock Type Semi-sinusoid
Peel Length 10 mm ... 12 mm
Acceleration 3.12g
Product Type Grounding terminal block
Open sidewall Yes
Grounding foot Yes
Number of rows 1
Surge Category Iii
Nominal Section 2.5 mm²
Number of poles 1
Test Directions X, Y, and Z axes
Type of mounting NS 35/7.5
Depth at NS 35/15 44.3 mm
Depth at NS 35/7.5 36.8 mm
Test Specification DIN EN 50155 (VDE 0115-200):2022-06
Degree of pollution 3
Field of Employment Railway industry
Insulating material PA
AWG Conductor Section (Converted according to IEC)
Duration of the crash 18 ms
Number of connections 2
Test duration per axis 5 h
Rigid conductor section 0.5 mm² ... 4 mm²
Insulating material group I
Flexible conductor section 0.75 mm² ... 4 mm²
Ambient Temperature (Drive) -5 °C ... 70 °C
Flexible Wire Section [AWG] 18 ... 12 (Converted according to IEC)
Ambient Temperature (Service) -60 °C ... 105 °C (for max. short-term operating temperature, see RTI Elec.)
Standard-compliant connection IEC 60947-7-2
Ambient Temperature (Mounting) -5 °C ... 70 °C
Dimensioning Transient Voltage 8 kV
Number of connections per floor 2
Number of collisions per steering 3
Flammability class according to UL 94 V0
NFPA 130 Flue Gas Toxicity (SMP 800C) approved
Static use of cold insulating material -60 °C
Ambient Temperature (Storage/Transport) -25 °C ... 60 °C (for a short time, no more than 24 hours, -60 °C to +70 °C)
Permissible air humidity (storage/transport) 30 % ... 70 %
Flammability of NFPA 130 Surfaces (ASTM E 162) approved
Maximum Dissipated Power with Nominal Condition 0.77 W
Flexible cable section (toe cap with plastic sleeve) 0.5 mm² ... 2.5 mm²
Fire protection for rail vehicles (DIN EN 45545-2) R22 HL 1 - HL 3
Fire protection for rail vehicles (DIN EN 45545-2) R23 HL 1 - HL 3
Fire protection for rail vehicles (DIN EN 45545-2) R24 HL 1 - HL 3
Fire protection for rail vehicles (DIN EN 45545-2) R26 HL 1 - HL 3
Flexible cable section (toe cap without plastic sleeve) 0.5 mm² ... 2.5 mm²
NFPA 130 Specific Optical Flue Gas Density (ASTM E 662) approved
Relative Insulating Material Temperature Index (Elec., UL 746 B) 130 °C