Parameter Hodnota
GTIN 4046356714303
Orderkey 2801163
Catalog page Page 41 (C-4-2017)
Packing unit 1 pc
Note (General) The device is intended for touch proof installation in a housing. Ensure that there is a gap of at least 8 mm between the active and grounded parts in the connection area.
Country of origin DE (Germany)
(Connection data) (L-) - G
Custom tariff number 85363030
(Ambient conditions) PBT-FR
Altitude (Dimensions) ≤ 2000 m (amsl (above mean sea level))
Type (Ambient conditions) DIN rail module, two-section, divisible
(Additional descriptions) ≤ 3.6 kV (at 40 kA)
Color (Ambient conditions) jet black RAL 9005
SPD Type (Connection data) 1
Depth (Key Commercial Data) 65.7 mm (incl. DIN rail 7.5 mm)
Width (Key Commercial Data) 53.4 mm
EN type (Ambient conditions) T1 / T2
Height (Key Commercial Data) 89.8 mm
Shock (operation) (Dimensions) 60g (Half-sine / 11 ms / 3x ±X, ±Y, ±Z)
Degree of protection (Dimensions) IP20 (only when all terminal points are used)
Nominal voltage (Connection data) 800 V DC
Accessibility (Ambient conditions) Accessible
Mounting type (Ambient conditions) DIN rail: 35 mm
Vibration (operation) (Dimensions) 7.5g (5-500 Hz/2.5 h/XYZ)
Mode of protection (Connection data) (L+) - (L-)
Weight per Piece (excluding packing) 365.400 g
Housing material (Ambient conditions) PA 6.6-FR
Tightening torque (UL specifications) 30 lbf-in.
Horizontal pitch (Key Commercial Data) 3 Div.
Mode of protection (Ambient conditions) (L+) - (L-)
Degree of pollution (Ambient conditions) 2
SPD failure behavior (Ambient conditions) OCM (Open-circuit mode)
(Protective circuit DC voltage side (DC)) 4.5 Nm (25 mm² ... 35 mm²)
Installation location (Ambient conditions) Inside
Response time tA (Additional descriptions) ≤ 25 ns
Standards/regulations (UL connection data) EN 50539-11 2013
Power distribution system (Connection data) DC PV
Ambient temperature (operation) (Dimensions) -40 °C ... 80 °C
IEC test classification (Ambient conditions) PV I / II
Connection configuration (Ambient conditions) Y configuration
Permissible humidity (operation) (Dimensions) 5 % ... 95 %
Nominal discharge current In (Connection data) 20 kA
Residual current IPE (Additional descriptions) ≤ 20 µA DC
Conductor cross section AWG (UL specifications) 10 ... 2
Rated load current IL (Additional descriptions) 80 A
Residual voltage Ures (Additional descriptions) ≤ 2.6 kV (at In)
Voltage protection rating VPR (Connection data) 2 kV
Surge protection fault message (Ambient conditions) optical
Ambient temperature (storage/transport) (Dimensions) -40 °C ... 80 °C
Insulation resistance Riso (Additional descriptions) > 5 GΩ (at 500 V DC)
Short-circuit current rating (SCCR) (Connection data) 50 kA
Voltage protection level Up (Additional descriptions) ≤ 2.6 kV
Screw thread (Protective circuit DC voltage side (DC)) M5
Standby power consumption PC (Additional descriptions) ≤ 25 mVA
Stripping length (Protective circuit DC voltage side (DC)) 16 mm
Connection method (Protective circuit DC voltage side (DC)) Fork-type cable lug
Continuous operating current ICPV (Additional descriptions) < 20 µA
Flammability rating according to UL 94 (Ambient conditions) V-0
Maximum continuous operating voltage MCOV (Connection data) 800 V DC
Tightening torque (Protective circuit DC voltage side (DC)) 3 Nm (1,5 mm² ... 16 mm²)
Short-circuit current rating ISCPV (Additional descriptions) 2000 A
Distance between live and grounded parts (Ambient conditions) 8 mm
Nominal discharge current (8/20) µs (Additional descriptions) 15 kA
Maximum discharge current Imax(8/20) µs (Additional descriptions) 40 kA
Total discharge current Itotal(8/20) µs (Additional descriptions) 40 kA
Installation location of the disconnect device (Ambient conditions) Internal
Maximum continuous operating voltage UCPV (Additional descriptions) 720 V DC
Total discharge current Itotal(10/350) µs (Additional descriptions) 7 kA
Conductor cross section AWG (Protective circuit DC voltage side (DC)) 15 ... 2
Conductor cross section solid (Protective circuit DC voltage side (DC)) 1.5 mm² ... 35 mm²
Impulse discharge current (10/350) µs, charge (Additional descriptions) 2.5 As
Conductor cross section flexible (Protective circuit DC voltage side (DC)) 1.5 mm² ... 16 mm²
Impulse discharge current (10/350) µs, peak value limp (Additional descriptions) 5 kA
Impulse discharge current (10/350) µs, specific energy (Additional descriptions) 6.25 kJ/Ω

Popis produktu

Lightning surge / current protection device for isolated and grounded 2-pole photovoltaic 600V DC DC systems, for rail mounting, 3-pole base element, three plug-in protection elements with temperature
Kľúčové vlastnosti
  • Priemyselná kvalita
  • V súlade s RoHS
  • Certifikácia CE
  • 1-ročná záruka

Dokumenty k produktu

Dátový list

Technické špecifikácie a údaje o výkone

Používateľská príručka

Návod na inštaláciu a obsluhu

Top