Kľúčové špecifikácie
GTIN: 4055626620657
Orderkey: 1044183
(Drawings):
Catalog page: Page 50 (C-4-2019)
Informácie o dodávateľovi
Produkty: 0
Zvyčajne sa odosiela do 2-3 pracovných dní
Zaručená kvalita
Rýchle doručenie
Technická podpora

Technické špecifikácie

Parameter Hodnota
GTIN 4055626620657
Orderkey 1044183
(Drawings)
Catalog page Page 50 (C-4-2019)
Packing unit 1
Note (General) The device is intended for touch proof installation in a housing. Ensure that there is a gap of at least 8 mm between the active and grounded parts in the connection area.
Depth (Drawings) 65.7 mm (incl. DIN rail 7.5 mm)
Width (Drawings) 71.2 mm
ETIM 5.0 (eCl@ss) EC000381
ETIM 6.0 (eCl@ss) EC000381
ETIM 7.0 (eCl@ss) EC000381
Height (Drawings) 89.8 mm
Custom tariff number 85363030
(Ambient conditions) PBT-FR
Altitude (Dimensions) ≤ 3000 m (amsl (above mean sea level))
Type (Ambient conditions) DIN rail module, two-section, divisible
(Additional descriptions) ≤ 700 µA AC
Color (Ambient conditions) jet black RAL 9005
Horizontal pitch (Drawings) 4 Div.
(Standards and Regulations) For details about hazardous substances go to tab “Downloads”, Category “Manufacturer's declaration”
EN type (Ambient conditions) T1 / T2
eCl@ss 4.0 (Classifications) 27130800
eCl@ss 4.1 (Classifications) 27130800
eCl@ss 5.0 (Classifications) 27130800
eCl@ss 5.1 (Classifications) 27130800
eCl@ss 6.0 (Classifications) 27130800
eCl@ss 7.0 (Classifications) 27130802
eCl@ss 8.0 (Classifications) 27130802
eCl@ss 9.0 (Classifications) 27130802
Dimensional drawing (Drawings)
Shock (operation) (Dimensions) 25g (Half-sine / 11 ms / 3x ±X, ±Y, ±Z)
Degree of protection (Dimensions) IP20 (only when all terminal points are used)
Accessibility (Ambient conditions) Accessible
Mounting type (Ambient conditions) DIN rail: 35 mm
Vibration (operation) (Dimensions) 5g (5-500 Hz/2.5 h/XYZ)
Housing material (Ambient conditions) PA 6.6-FR
China RoHS (Standards and Regulations) Environmentally Friendly Use Period = 50
REACh SVHC (Standards and Regulations) Lead 7439-92-1
Mode of protection (Ambient conditions) (DC+) - (DC-)
Standards/regulations (Connection data) EN 50539-11 2013
Degree of pollution (Ambient conditions) 2
SPD failure behavior (Ambient conditions) OCM (Open-circuit mode)
(Protective circuit DC voltage side (DC)) 4.5 Nm (25 mm² ... 35 mm²)
Installation location (Ambient conditions) Interior
Response time tA (Additional descriptions) ≤ 25 ns
Ambient temperature (operation) (Dimensions) -40 °C ... 85 °C
IEC test classification (Ambient conditions) PV I / II
Connection configuration (Ambient conditions) Y configuration
Permissible humidity (operation) (Dimensions) 5 % ... 95 %
Residual current IPE (Additional descriptions) ≤ 40 µA DC
Rated load current IL (Additional descriptions) 80 A
Surge protection fault message (Ambient conditions) optical
Ambient temperature (storage/transport) (Dimensions) -40 °C ... 85 °C
Insulation resistance Riso (Additional descriptions) > 5 GΩ (at 500 V DC)
Screw thread (Protective circuit DC voltage side (DC)) M5
Standby power consumption PC (Additional descriptions) ≤ 25 mVA
Stripping length (Protective circuit DC voltage side (DC)) 16 mm
Connection method (Protective circuit DC voltage side (DC)) Fork-type cable lug
Continuous operating current ICPV (Additional descriptions) < 20 µA
Flammability rating according to UL 94 (Ambient conditions) V-0
Tightening torque (Protective circuit DC voltage side (DC)) 3 Nm (1.5 mm² ... 16 mm²)
Short-circuit current rating ISCPV (Additional descriptions) 2000 A
Distance between live and grounded parts (Ambient conditions) 8 mm
Nominal discharge current (8/20) µs (Additional descriptions) 15 kA
Maximum discharge current Imax(8/20) µs (Additional descriptions) 40 kA
Installation location of the disconnect device (Ambient conditions) Internal
Maximum continuous operating voltage UCPV (Additional descriptions) 1170 V DC
Total discharge current Itotal(8/20) µs (Additional descriptions) 40 kA
Conductor cross section AWG (Protective circuit DC voltage side (DC)) 15 ... 2
Total discharge current Itotal(10/350) µs (Additional descriptions) 10 kA
Conductor cross section solid (Protective circuit DC voltage side (DC)) 1.5 mm² ... 35 mm²
Impulse discharge current (10/350) µs, charge (Additional descriptions) 2.5 As
Conductor cross section flexible (Protective circuit DC voltage side (DC)) 1.5 mm² ... 16 mm²
Impulse discharge current (10/350) µs, peak value limp (Additional descriptions) 5 kA
Impulse discharge current (10/350) µs, specific energy (Additional descriptions) 6.25 kJ/Ω

Popis produktu

Lightning current/surge arrester for 1000 V DC 2-pole isolated DC systems, for rail mounting, 4-pole base element, four plug-in protection elements with temperature control, status signaling on each c
Kľúčové vlastnosti
  • Priemyselná kvalita
  • V súlade s RoHS
  • Certifikácia CE
  • 1-ročná záruka

Technické detaily

Dimensional drawing

Dokumenty k produktu

Dátový list

Technické špecifikácie a údaje o výkone

Používateľská príručka

Návod na inštaláciu a obsluhu

Top