VAL-MS-T1/T2 1000DC-PV/2+V-FM - VAL-MS-T1/T2 1000DC-PV/2+V-FM 2801161 PHOENIX CONTACT Lightning/surge arrester for 2-pos. isolated 1000 V DC..
Na sklade Horúci produkt

VAL-MS-T1/T2 1000DC-PV/2+V-FM

VAL-MS-T1/T2 1000DC-PV/2+V-FM 2801161 PHOENIX CONTACT Lightning/surge arrester for 2-pos. isolated 1000 V DC..

$0.00 USD
3859 na sklade
Kľúčové špecifikácie
: PV T2
Note: The device is intended for touch proof installation in a housing. Ensure that there is a gap of at least 8 mm between the active and grounded parts in the connection area.
Type: DIN rail module, two-section, divisible
Color: jet black RAL 9005
Informácie o dodávateľovi
Produkty: 0
Zvyčajne sa odosiela do 2-3 pracovných dní
Zaručená kvalita
Rýchle doručenie
Technická podpora

Technické špecifikácie

Parameter Hodnota
PV T2
Note The device is intended for touch proof installation in a housing. Ensure that there is a gap of at least 8 mm between the active and grounded parts in the connection area.
Type DIN rail module, two-section, divisible
Color jet black RAL 9005
Depth 65.5 mm
Width 53.4 mm
Height 99 mm
EN type T1
Altitude ≤ 2000 m (amsl (above mean sea level))
SPD Type 4 (for Type 2 photovoltaic applications)
SPD design Combination type
Nom. voltage 875 V AC
Screw thread M2
Accessibility Accessible
Mounting type DIN rail: 35 mm
Connection name Remote fault indicator contact
Number of ports One
Horizontal pitch 3 Div.
Housing material PA 6.6-FR
Pollution degree 2
Stripping length 7 mm
Connection method Screw connection
Operating current 5 mA AC ... 1.5 A AC
Operating voltage 5 V AC ... 250 V AC
Shock (operation) 60g (Half sine/11 ms/3x XYZ)
Tightening torque 0.25 Nm
Mode of protection (L+) - (L-)
Switching function PDT contact
Degree of protection IP20 (only when all terminal points are used)
Residual current IPE ≤ 20 µA DC
SPD failure behavior OCM (Open-circuit mode)
Installation location Inside
Rated load current IL 80 A
Vibration (operation) 7.5g (5-500 Hz/2.5 h/XYZ)
IEC test classification PV T1
Connection configuration Y configuration
Response time tA(L-) -PE ≤ 25 ns
Standards/specifications EN 50539-11 2013
Power distribution system 1
Response time tA(L+) - PE ≤ 25 ns
Insulation resistance Riso > 5 GΩ (at 500 V DC)
Conductor cross section AWG 28 ... 16
Open circuit voltage UOCSTC ≤ 875 V DC
Response time tA(L+) - (L-) ≤ 25 ns
Standby power consumption PC ≤ 25 mVA
Residual voltage Ures(L+) - PE ≤ 3.5 kV (at In)
Residual voltage Ures(L-) - PE ≤ 3.5 kV (at In)
Surge protection fault message Optical, remote indicator contact
Ambient temperature (operation) -40 °C ... 80 °C
Permissible humidity (operation) 5 % ... 95 %
Residual voltage Ures(L+) - (L-) ≤ 3.5 kV (at In)
Continuous operating current ICPV < 20 µA
Conductor cross section solid max. 1.5 mm²
Conductor cross section solid min. 0.14 mm²
Short-circuit current rating ISCPV 1000 A
Nominal discharge current (8/20) µs 15 kA
Nominal discharge current In(L+) - G 20 kA
Nominal discharge current In(L-) - G 20 kA
Voltage protection level Up(L+) - PE ≤ 3.5 kV
Voltage protection level Up(L-) - PE ≤ 3.5 kV
Conductor cross section flexible max. 1.5 mm²
Conductor cross section flexible min. 0.14 mm²
Voltage protection rating VPR (L-) -G 3 kV
Flammability rating according to UL 94 V-0
Voltage protection level Up(L+) - (L-) ≤ 3.5 kV
Voltage protection rating VPR (L+) - G 3 kV
Ambient temperature (storage/transport) -40 °C ... 80 °C
Nominal discharge current In(L+) - (L-) 20 kA
Distance between live and grounded parts 8 mm
Maximum discharge current Imax(8/20) µs 40 kA
Maximum continuous operating voltage UCPV 1050 V DC
Total discharge current ITotal(8/20) µs 40 kA
Voltage protection rating VPR (L+) - (L-) 3 kV
Total discharge current ITotal(10/350) µs 5 kA
Installation location of the disconnect device Internal
Impulse discharge current (10/350)˽µs, charge 2.5 As
Nominal discharge current In(8/20) µs (L+) - PE 15 kA
Nominal discharge current In(8/20) µs (L-) - PE 15 kA
Maximum continuous operating voltage MCOV (L+) - G 1050 V DC
Maximum continuous operating voltage MCOV (L-) - G 1050 V DC
Maximum discharge current Imax(8/20) µs (L+) - PE 40 kA
Maximum discharge current Imax(8/20) µs (L-) - PE 40 kA
Nominal discharge current In(8/20) µs (L+) - (L-) 15 kA
Maximum discharge current Imax(8/20) µs (L+) - (L-) 40 kA
Maximum continuous operating voltage MCOV (L+) - (L-) 1050 V DC
Impulse discharge current (10/350) µs, peak value limp 5 kA
Impulse discharge current (10/350)˽µs, specific energy 6.25 kJ/Ω

Popis produktu

Lightning surge / current protection device for isolated and grounded 2-pole photovoltaic 1000V DC direct current systems, for rail mounting, 3-pole base element with remote indication contact, three
Kľúčové vlastnosti
  • Priemyselná kvalita
  • V súlade s RoHS
  • Certifikácia CE
  • 1-ročná záruka

Dokumenty k produktu

Dátový list

Technické špecifikácie a údaje o výkone

Používateľská príručka

Návod na inštaláciu a obsluhu