Čas služby: pondelok až piatok 9:00-18:00
VAL-MS 230IT/3+1-FM - VAL-MS 230IT/3+1-FM 2858551 PHOENIX CONTACT Type 2 surge arrester
Na sklade Horúci produkt

VAL-MS 230IT/3+1-FM

VAL-MS 230IT/3+1-FM 2858551 PHOENIX CONTACT Type 2 surge arrester

$0.00 USD
3262 na sklade
Kľúčové špecifikácie
GTIN: 4046356099158
Note: Made to Order (non-returnable)
Orderkey: 2858551
(General): 440 V AC (120 min / withstand mode)
Informácie o dodávateľovi
Produkty: 0
Zvyčajne sa odosiela do 2-3 pracovných dní
Zaručená kvalita
Rýchle doručenie
Technická podpora

Technické špecifikácie

Parameter Hodnota
GTIN 4046356099158
Note Made to Order (non-returnable)
Orderkey 2858551
(General) 440 V AC (120 min / withstand mode)
Packing unit 1 pc
Country of origin DE (Germany)
(Connection data) EN 61643-11 2012
Custom tariff number 85363010
(Ambient conditions) PBT
(Protective circuit) 1 A DC
Altitude (Dimensions) ≤ 2000 m (amsl (above mean sea level))
Type (Ambient conditions) DIN rail module, two-section, divisible
Color (Ambient conditions) jet black RAL 9005
Depth (Key Commercial Data) 65.7 mm (incl. DIN rail 7.5 mm)
Width (Key Commercial Data) 71 mm
EN type (Ambient conditions) T2
Height (Key Commercial Data) 98.7 mm
Nominal voltage UN (General) 240/415 V AC (TN-S)
(Indicator/remote signaling) 4.5 Nm (25 mm² ... 35 mm²)
Nominal frequency fN (General) 50 Hz (60 Hz)
Residual current IPE (General) ≤ 5 µA
Shock (operation) (Dimensions) 25g (Half-sine / 11 ms / 3x ±X, ±Y, ±Z)
Rated load current IL (General) 80 A
Response time tA(L-N) (General) ≤ 25 ns
Response time tA(L-PE) (General) ≤ 100 ns
Response time tA(N-PE) (General) ≤ 100 ns
Degree of protection (Dimensions) IP20 (only when all terminal points are used)
Screw thread (Protective circuit) M2
TOV behavior at UT(L-N) (General) 415 V AC (5 s / withstand mode)
Mounting type (Ambient conditions) DIN rail: 35 mm
TOV behavior at UT(N-PE) (General) 1200 V AC (200 ms / withstand mode)
Vibration (operation) (Dimensions) 5g (10 ... 500 Hz / 2.5 h / X, Y, Z)
Residual voltage Ures(L-N) (General) ≤ 2 kV (at In)
Weight per Piece (excluding packing) 398.360 g
Housing material (Ambient conditions) PA 6.6
Residual voltage Ures(L-PE) (General) ≤ 2.2 kV (at In)
Residual voltage Ures(N-PE) (General) ≤ 0.4 kV (at In)
Stripping length (Protective circuit) 7 mm
Connection method (Protective circuit) Plug-in/screw connection via COMBICON
Horizontal pitch (Key Commercial Data) 4 Div.
Operating current (Protective circuit) 5 mA AC ... 750 mA AC
Operating voltage (Protective circuit) 5 V AC ... 250 V AC
Standby power consumption PC (General) ≤ 525 mVA
Tightening torque (Protective circuit) 0.25 Nm
Mode of protection (Ambient conditions) L-N
Standards/regulations (Connection data) IEC 61643-11 2011
Switching function (Protective circuit) PDT contact
Degree of pollution (Ambient conditions) 2
Number of positions (Ambient conditions) 4
Screw thread (Indicator/remote signaling) M5
Voltage protection level Up(L-N) (General) ≤ 2 kV
Voltage protection level Up(L-PE) (General) ≤ 2.2 kV
Voltage protection level Up(N-PE) (General) ≤ 1.5 kV
Ambient temperature (operation) (Dimensions) -40 °C ... 80 °C
IEC power supply system (Ambient conditions) TN-S
IEC test classification (Ambient conditions) II
Short-circuit current rating ISCCR (General) 25 kA
Max. backup fuse with branch wiring (General) 125 A (gG)
Maximum continuous voltage UC(N-PE) (General) 260 V AC
Permissible humidity (operation) (Dimensions) 5 % ... 95 %
Stripping length (Indicator/remote signaling) 16 mm
Connection method (Indicator/remote signaling) Fork-type cable lug
Tightening torque (Indicator/remote signaling) 3 Nm (1,5 mm² ... 16 mm²)
Conductor cross section AWG (Protective circuit) 28 ... 16
Nominal discharge current In(8/20) µs (General) 20 kA
Conductor cross section solid (Protective circuit) 0.14 mm² ... 1.5 mm²
Maximum discharge current Imax(8/20) µs (General) 40 kA
Follow current interrupt rating Ifi(N-PE) (General) 100 A (260 V)
Surge protection fault message (Ambient conditions) Optical, remote indicator contact
Ambient temperature (storage/transport) (Dimensions) -40 °C ... 80 °C
Conductor cross section flexible (Protective circuit) 0.14 mm² ... 1.5 mm²
Max. backup fuse with V-type through wiring (General) 80 A (gG)
Maximum continuous operating voltage UC(L-N) (General) 385 V AC
Maximum continuous operating voltage UC(L-PE) (General) 385 V AC
Conductor cross section AWG (Indicator/remote signaling) 15 ... 2
Conductor cross section solid (Indicator/remote signaling) 1.5 mm² ... 35 mm²
Flammability rating according to UL 94 (Ambient conditions) V-0
Conductor cross section flexible (Indicator/remote signaling) 1.5 mm² ... 16 mm²

Popis produktu

Surge arrester consisting of base element and plug-in protections, for installation on NS 35/7.5, execution: 230 V AC IP system, 3 + 1 circuit.
Kľúčové vlastnosti
  • Priemyselná kvalita
  • V súlade s RoHS
  • Certifikácia CE
  • 1-ročná záruka

Dokumenty k produktu

Dátový list

Technické špecifikácie a údaje o výkone

Používateľská príručka

Návod na inštaláciu a obsluhu