UTTB 4 BN - UTTB 4 BN 1484265 PHOENIX CONTACT Double-deck terminal block, nominal voltage: 800 V, nominal current: 30 A,..
Na sklade Horúci produkt

UTTB 4 BN

UTTB 4 BN 1484265 PHOENIX CONTACT Double-deck terminal block, nominal voltage: 800 V, nominal current: 30 A,..

$3.12 USD
3236 na sklade
Kľúčové špecifikácie
: Machine building
Color: brown
Width: 6.2 mm
Height: 69.9 mm
Informácie o dodávateľovi
Produkty: 0
Zvyčajne sa odosiela do 2-3 pracovných dní
Zaručená kvalita
Rýchle doručenie
Technická podpora

Technické špecifikácie

Parameter Hodnota
Machine building
Color brown
Width 6.2 mm
Height 69.9 mm
Potentials 2
Typ produktu Multi-level terminal block
Screw thread M3
Mounting type NS 35/7,5
Number of rows 2
End cover width 2.2 mm
Nominal current 30 A
Nominal voltage 800 V
Open side panel Yes
Stripping length 9 mm
Cross section AWG 26 ... 10 (converted acc. to IEC)
Tightening torque 0.6 ... 0.8 Nm
Depth on NS 35/15 72.5 mm
Area of application Railway industry
Degree of pollution 3
Depth on NS 35/7,5 65 mm
Insulating material PA
Rated surge voltage 8 kV
Maximum load current 36 A (with 6 mm² conductor cross section)
Overvoltage category III
Nominal cross section 4 mm²
Number of connections 4
Insulating material group I
Internal cylindrical gage A4
Conductor cross section rigid 0.14 mm² ... 6 mm²
Ambient temperature (assembly) -5 °C ... 70 °C
Ambient temperature (actuation) -5 °C ... 70 °C
Ambient temperature (operation) -60 °C ... 105 °C (max. short-term operating temperature RTI Elec.)
Number of connections per level 2
Conductor cross section flexible 0.14 mm² ... 6 mm²
Connection in acc. with standard IEC 60947-7-1
Flammability rating according to UL 94 V0
Smoke gas toxicity NFPA 130 (SMP 800C) passed
Ambient temperature (storage/transport) -25 °C ... 60 °C (for a short time, not exceeding 24 h, -60 °C to +70 °C)
Conductor cross section, flexible [AWG] 26 ... 10 (converted acc. to IEC)
Permissible humidity (storage/transport) 30 % ... 70 %
Surface flammability NFPA 130 (ASTM E 162) passed
2 conductors with same cross section, solid 0.14 mm² ... 1.5 mm²
2 conductors with same cross section, flexible 0.14 mm² ... 1.5 mm²
Static insulating material application in cold -60 °C
Fire protection for rail vehicles (DIN EN 45545-2) R22 HL 1 - HL 3
Fire protection for rail vehicles (DIN EN 45545-2) R23 HL 1 - HL 3
Fire protection for rail vehicles (DIN EN 45545-2) R24 HL 1 - HL 3
Fire protection for rail vehicles (DIN EN 45545-2) R26 HL 1 - HL 3
Specific optical density of smoke NFPA 130 (ASTM E 662) passed
Flexible conductor cross section (ferrule with plastic sleeve) 0.14 mm² ... 4 mm²
Relative insulation material temperature index (Elec., UL 746 B) 130 °C
Conductor cross-section flexible (ferrule without plastic sleeve) 0.14 mm² ... 4 mm²
2 conductors with same cross section, flexible, with ferrule without plastic sleeve 0.14 mm² ... 1.5 mm²
2 conductors with the same cross section, flexible, with TWIN ferrule with plastic sleeve 0.5 mm² ... 2.5 mm²

Popis produktu

Double-level terminal block, nom. voltage: 800 V, nominal current: 30 A, connection method: Screw connection, 1st and 2nd level, Rated cross section: 4 mm2, cross section: 0.14 mm2 - 6 mm2, mounting t