Čas služby: pondelok až piatok 9:00-18:00
USFC21 - USFC21 SF-C21 PANASONIC Safety control unit for safety light curtain and other safety products, 8 inputs 24V..
Na sklade Horúci produkt

USFC21

USFC21 SF-C21 PANASONIC Safety control unit for safety light curtain and other safety products, 8 inputs 24V..

$0.00 USD
4642 na sklade
Kľúčové špecifikácie
Item: Specifications
Weight: Net weight: 190 g approx.Gross weight: 320 g approx.
Product: Safety Control Unit
Material: Main unit enclosure: Polycarbonate / ABS polymer alloyEnclosure: Polycarbonate
Informácie o dodávateľovi
PANASONIC
PANASONIC
Produkty: 4316
Zvyčajne sa odosiela do 2-3 pracovných dní
Zaručená kvalita
Rýchle doručenie
Technická podpora

Technické špecifikácie

Parameter Hodnota
Item Specifications
Weight Net weight: 190 g approx.Gross weight: 320 g approx.
Product Safety Control Unit
Material Main unit enclosure: Polycarbonate / ABS polymer alloyEnclosure: Polycarbonate
PFHD/ MTTFD 9.73 x 10−10/ 100 years or more
Part Number SF-C21
Cable length 100 m328.084 ftor less
Názov produktu Safety Control Unit SF-C21
Product Number SF-C21
Pollution degree 2
Connecting method Input / output and power supply: Detachable spring cage termina l blocksRS-485: Detachable spring-cage terminal blockUSB: Mini-B male
Related standards IEC 60947-1, IEC 60947-5-1, IEC 60947-5-2, IEC 60947-5-5, IEC 60947-5-8, IEC 61496-1, IEC TS 62046, ISO 13851
Interlock function Incorporated
Operating altitude 2,000 m6561.680 ftor less(Note) Do not use or store this device in a pressurized environment beyond the atmospheric pressure at sea level.
Vibration resistance 5 to 8.4 Hz frequency, 3.5 mm0.138 inhalf amplitude, 8.4 to 150 Hz frequency, Max. acceleration 9.8 m/s2(1 G), in X, Y and Z directions for two hours each (IEC / EN 60068-2-6)
Logic setting function Input mode, control mode, output mode, reset mode, auxiliary ou tput mode
Excess voltage category II
Muting indicator output Semiconductor photo MOS relay output x 1- Maximum load current: 60 mA- Supply voltage: Same as the voltage of the power supply for internal- Residual voltage: 2.5 V or less- Leakage current: 100 μA or less (Including power supply OFF condition)
Lockout release function Incorporated
Logic selection function No.0: Customization controlNo.1: Overall stop controlNo.2: Parallel muting controlNo.3: Sequential muting controlNo.4: Partial stop control 1No.5: Partial stop control 2No.6: Two-hand controlNo.7: OR controlNo.8: Operation mode selection control
Safety input (IN1 to IN8) 2 inputs x 4, Rated voltage: Same as the voltage of the power supply for internal
Applicable standards : EMC IEC 61000-6-2, IEC 61326-3-1, EN 55011
Startup time after power on 2 sec. or less
Applicable standards : Safety IEC 61508-1 to 3, EN 61508-1 to 3 (SIL3), ISO 13849-1:2015 (Category 4, PLe), IEC 61131-2, IEC 61010-2-201, IEC 62061 (SILCL3), UL 61010-1, UL 61010-2-201, UL 1998
Control output (OUT1 to OUT4) PNP open-collector transistor with 2 outputs x 2- Maximum source current: 300 mA / output- Applied voltage: Same as the voltage of the power supply for external- Residual voltage: 2.5 V or less- Leakage current: 100 μA or less (Including power supply OFF condition)
Communication function (MODBUS RTU) Interface: RS-485Protocol: MODBUS RTUMaximum transmission distance: 100 m328.084 ftMaximum number of units that can be connected: 8 units (slaves)
External device monitoring function Incorporated
Safety input (IN1 to IN8) : ON level Input voltage: 18 VInput current: 3.5 mA
Muting indicator output : Output mode ON when muting / override
Safety input (IN1 to IN8) : OFF level Input voltage: 5 VInput current: 1.0 mA
Muting indicator output : Response time 10 ms or less
Applicable regulations and certifications CE Marking (Machinery Directive, EMC Directive, RoHS Directive), UKCA Marking [Supply of Machinery (Safety)Regulations, EMC Regulations, RoHS Regulations], TÜV SÜD certification, Korea's Radio Waves Act conformity registration
Environmental resistance:Ambient humidity 30 to 85 % RH, Storage: 30 to 85 % RH
Environmental resistance:Shock resistance 147 m/s2(15 G) 11 ms in X, Y and Z directions for three times each (IEC / EN 60068-2-27)
Supply voltage : Power supply for external 24 V DC+10-15% Ripple P-P10 % or less(Note) "Power supply for external" is the power supply for control output / auxiliary output. The power supplies for internal and external are insulated.(Note) The power supply unit connected to this device must satisfy the conditions below.- Output voltage within 20.4 V to 26.4 V DC (Ripple P-P: 10 % or less.)- Power supply unit SELV (safety extra low voltage) / PELV (protected extra low voltage) conforming to the EMC Directive and Low-voltage Directive (In case CE Marking conformity is required.)- Power supply unit conforming to the Low-voltage Directive and with an output of 100 VA or less- Power supply unit SELV (safety extra low voltage) / PELV (protected extra low voltage) conforming to the EMC Regulations and Low-voltage Regulations (In case UKCA Marking conformity is required.)- Power supply unit with an output holding time of 20 ms or more.- Power supply unit corresponding to CLASS 2 (In case C-TÜV US Listing Mark conformity is required.)
Supply voltage : Power supply for internal 24 V DC+10-15% Ripple P-P10 % or less(Note) "Power supply for internal" is the power supply for safety input. The power supplies for internal and external are insulated.(Note) The power supply unit connected to this device must satisfy the conditions below.- Output voltage within 20.4 V to 26.4 V DC (Ripple P-P: 10 % or less.)- Power supply unit SELV (safety extra low voltage) / PELV (protected extra low voltage) conforming to the EMC Directive and Low-voltage Directive (In case CE Marking conformity is required.)- Power supply unit conforming to the Low-voltage Directive and with an output of 100 VA or less- Power supply unit SELV (safety extra low voltage) / PELV (protected extra low voltage) conforming to the EMC Regulations and Low-voltage Regulations (In case UKCA Marking conformity is required.)- Power supply unit with an output holding time of 20 ms or more.- Power supply unit corresponding to CLASS 2 (In case C-TÜV US Listing Mark conformity is required.)
Control output (OUT1 to OUT4) : Output mode True: ONFalse: OFF
Safety input (IN1 to IN8) : Input impedance 4.7 KΩ approx.
Environmental resistance:Ambient temperature -10 to +55 ℃+14 to +131 ℉(No dew condensation or icing allowed), Storage: -25 to +60 ℃-13 to +140 ℉
Control output (OUT1 to OUT4) : Response time OFF response: 10 ms or lessON response: 100 ms or less
Environmental resistance:Degree of protection IP20 (IEC)(must be installed in a control panel with protectio n IP54 or higher)
Environmental resistance:Insulation resistance 20 MΩ, or more, with 500 V DC megger(All inputs connected together - USB port, all inputs connected together - RS-485 port, USB port - RS-485 port, between all supply terminals connected together and enclosure, all outputs connected together - all input connected together, all outputs connected together - USB port, all outputs connected together - RS-485 port)
Current consumption : Power supply for external 100 mA or less(Note) "Power supply for external" is the power supply for control output / auxiliary output. The power supplies for internal and external are insulated.(Note) The power supply unit connected to this device must satisfy the conditions below.- Output voltage within 20.4 V to 26.4 V DC (Ripple P-P: 10 % or less.)- Power supply unit SELV (safety extra low voltage) / PELV (protected extra low voltage) conforming to the EMC Directive and Low-voltage Directive (In case CE Marking conformity is required.)- Power supply unit conforming to the Low-voltage Directive and with an output of 100 VA or less- Power supply unit SELV (safety extra low voltage) / PELV (protected extra low voltage) conforming to the EMC Regulations and Low-voltage Regulations (In case UKCA Marking conformity is required.)- Power supply unit with an output holding time of 20 ms or more.- Power supply unit corresponding to CLASS 2 (In case C-TÜV US Listing Mark conformity is required.)
Current consumption : Power supply for internal 200 mA or less(Note) "Power supply for internal" is the power supply for safety input. The power supplies for internal and external are insulated.(Note) The power supply unit connected to this device must satisfy the conditions below.- Output voltage within 20.4 V to 26.4 V DC (Ripple P-P: 10 % or less.)- Power supply unit SELV (safety extra low voltage) / PELV (protected extra low voltage) conforming to the EMC Directive and Low-voltage Directive (In case CE Marking conformity is required.)- Power supply unit conforming to the Low-voltage Directive and with an output of 100 VA or less- Power supply unit SELV (safety extra low voltage) / PELV (protected extra low voltage) conforming to the EMC Regulations and Low-voltage Regulations (In case UKCA Marking conformity is required.)- Power supply unit with an output holding time of 20 ms or more.- Power supply unit corresponding to CLASS 2 (In case C-TÜV US Listing Mark conformity is required.)
Safety input (IN1 to IN8) : Rated input current 5 mA approx.
Auxiliary output(AUX1 to AUX4)(Non-safety output) PNP open-collector transistor with 1 output x 4- Maximum source current: 60 mA / output- Applied voltage: Same as the voltage of the power supply for external- Residual voltage: 2.5 V or less- Leakage current: 100 μA or less (Including power supply OFF condition)
Control output (OUT1 to OUT4) : ON delay function Incorporated
Environmental resistance:Voltage withstandability 1,000 V AC for one min.(All inputs connected together - USB port, all inputs connected together - RS-485 port, USB port - RS-485 port, between all supply terminals connected together and enclosure, all outputs connected together - all input connected together, all outputs connected together - USB port, all outputs connected together - RS-485 port)
Control output (OUT1 to OUT4) : OFF delayfu nction Incorporated
Muting indicator output : Short-circuit protection Incorporated
Control output (OUT1 to OUT4) : Short-circuit protection Incorporated
Safety input (IN1 to IN8) : Duration of detectable ON state 10 ms or more
Safety input (IN1 to IN8) : Duration of undetectable OFF state 0.7 ms or less
Auxiliary output(AUX1 to AUX4)(Non-safety output) : Response time 10 ms or less
Auxiliary output(AUX1 to AUX4)(Non-safety output) : Short-circuit protection Incorporated
Auxiliary output(AUX1 to AUX4)(Non-safety output) : Output mode (Factory defaults) AUX1: Negative logic of OUT1 / OUT2 (ON when OUT1 / OUT2 is OFF)AUX2: Negative logic of OUT3 / OUT4 (ON when OUT3 / OUT4 is OFF)AUX3: Reset trigger output (ON under reset release wait condition)AUX4: Lockout output (OFF when lockout)
Auxiliary output(AUX1 to AUX4)(Non-safety output) : Output mode (Any of the auxiliary outputs can be customized using the software tool) Negative logic of OUT1 / OUT2 (ON when OUT1 / OUT2 is OFF)Negative logic of OUT3 / OUT4 (ON when OUT3 / OUT4 is OFF)Positive logic of OUT1 / OUT2 (ON when OUT1 / OUT2 is ON)Positive logic of OUT3 / OUT4 (ON when OUT3 / OUT4 is ON)Outputs A, B, C, and D of diagnosis results of input blocks (ON when logic is true)Outputs E, F, and G of internal logic circuit diagnostic results (ON when logic is true)Reset trigger output (ON under reset release wait condition)Lockout output (OFF when lockout)Muting indicator output (ON when muting / override)Monitor output in response to IN1 to IN8 (ON when input)No output (normally OFF)

Popis produktu

Control unit for barriers and other safety products, Cat. 4(Ple) and SIL3, 4 inputs, 2 outputs, 8 pre-established logics according to cat regulations. 4 (Ple) and 1 customizable logic, self-diagnostic
Kľúčové vlastnosti
  • Priemyselná kvalita
  • V súlade s RoHS
  • Certifikácia CE
  • 1-ročná záruka

Dokumenty k produktu

Dátový list

Technické špecifikácie a údaje o výkone

Používateľská príručka

Návod na inštaláciu a obsluhu

Top