Kľúčové špecifikácie
: 230 V AC
Exit: 2 kV (Test Severity 3, Asymmetric)
AC OK: AcIn> 0.45 x ACN(ACN= 108 V AC)
Crash: 18 ms, 30g, per direction in space (according to IEC 60068-2-27)
Informácie o dodávateľovi
Produkty: 0
Zvyčajne sa odosiela do 2-3 pracovných dní
Zaručená kvalita
Rýchle doručenie
Technická podpora

Technické špecifikácie

Parameter Hodnota
230 V AC
Exit 2 kV (Test Severity 3, Asymmetric)
AC OK AcIn> 0.45 x ACN(ACN= 108 V AC)
Crash 18 ms, 30g, per direction in space (according to IEC 60068-2-27)
DC OK UOUT> 0.9 x UN(UN= 24 V DC)
Depth 53 mm
Width 136 mm
Yield Typ. 90% (120 V AC)
Colour green
Height 240 mm
Marked UL/C-UL Listed UL 61010-1
Signal 2 kV (Test Severity 3, Asymmetric)
Default closed
Digital 30 V AC 30 V DC 100 mA
tension 10 V (Test Severity 3)
Derating > 40 °C ... 50 °C (1%/K)
Diameter 5.6 mm
entrance 4 kV (Test Severity 3, Asymmetric)
Lock Type M12 Screw Lock
frequency 50 Hz
EN 61010-1 III (≤ 2000 m)
Inlet fuse 6.3 A (internal (device protection))
Ascent Time ≤ 12 ms (UOUT(10 % ... 90 %))
Criterion A Normal service behavior within the specified limits.
Criterion B Transient alteration of service behavior, which is corrected by the device itself.
Criterion C Temporary adverse effects on performance that are automatically corrected by the equipment or that can be reset by operating the control elements.
Observation Criterion A
Codification s
Input/Output asymmetric
Output power 240 W
Product Type Power supply
Fixing height ≤ 4000 m (> 2000 m, Derating: 10%/1000 m)
Voltage Error 70 %
Weather Class 4K26 (EN 60721-3-4)
Product Family TRIO POWER
Connection Time < 1 sec
Connection type M12 Cylindrical Connector
Frequency Range 80 MHz ... 1 GHz
Number of poles 3
Residual ripple ≤ 10 mVPP
Type of signage LED
Housing Material Metal
Number of phases 1,00
Protection Index IP67
Rules/Provisions IEC 61010-1
Type of mounting Wall Mounting
Dimming deviation < 1% (static load change 10% ... 90 %)
Network Structure Star Network (TN, TT, IT (PE))
Number of periods 25 periods
Operating Voltage > 85 V AC
Status Indication 2 x Green LED
AC Frequency Range 50 Hz ... 60 Hz ±10%
Current absorption 2.3 A (120 V AC)
Disconnect voltage < 85 V AC
Kind of protection I
Protection Circuit Protection against transient overvoltages; Varistor
Degree of pollution 3
Designation Signage AC OK
Download contact us 6 kV (Test Severity 3)
Input Voltage Range 120 V AC ... 240 V AC ±10%
Nominal power input 285 VA
Vibration (service) < 15 Hz, width ±2.5 mm (according to IEC 60068-2-6)
Frequency range (fN) 50 Hz ... 60 Hz ±10%
Test Field Intensity 10 V/m (Test Severity 3)
Interference emission Interference emission in accordance with EN 61000-6-3 (residential and commercial areas) and EN 61000-6-4 (industrial areas)
Low Voltage Directive Compliance with the Low Voltage Directive 2014/35/EU
Static boost derating > 40 °C ... 50 °C 1 %/K> 50 ... 60 °C 0.22 %/K (UN 230 V AC, PStat.Boost= PNx 1:25)
With protective paint No
Extra-current shut-off ≤ 25 A (typical)
Nominal Output Voltage 24 V DC ±1%
Interference resistance Immunity to interference according to EN 61000-6-1 (domestic use), EN 61000-6-2 (industrial use)
Short circuit resistant Yes
Denomination of standard Electrical Safety
Recirculation Resistance ≤ 35 V DC
Standards/Specifications EN 61000-3-2
Execution of the housings Aluminum (AlMg3)
Ground Shunt Current (PE) < 3.5 mA
Installation instructions Stackable: horizontal 20 mm, vertical up 50 mm, vertical down 100 mm
Mounting Distance Up/Down 50 mm / 100 mm
Rated Output Current (IN) 10 A
Dynamic Boost (IDyn.Boost) 15 A (5 sec)
MTBF (IEC 61709, SN 29500) > 850000 h (25 °C)
Static Boost (IBoost est.) 12.5 A (UN 230 V AC)
Maximum dielectric strength ≤ 300 V AC 15 sec
Nominal Input Voltage Range 120 V AC ... 240 V AC
Radiated spurious emissions EN 55016
Supply Voltage Voltage Type AC
Parallel connection possible Yes, for redundancy and power boost
Right/Left Mounting Distance 20 mm / 20 mm
Typical Country Grid Voltage 120 V AC
Ambient Temperature (Service) -25 °C ... 60 °C
Electromagnetic compatibility Compliance with EMC Directive 2014/30/EU
Inrush current integral (I2t) < 0.5 A2s
Network Failure Bridging Time > 17 ms (120 V AC)
Output Surge Protection (OVP) ≤ 30 V DC
Maximum Rated Load Dissipation < 25 W (120 V AC)
Input/Output Insulation Voltage 3 kV AC (type test)
Maximum Open Circuit Dissipation < 2 W (120 V AC)
Possibility of series connection Yes
Emission of Conducted Interference EN 55016
Permissible air humidity (service) ≤ 100% (at 25°C, non-condensing)
Shut-off current voltage limitation Typ. 25 A (after 1 ms)
Ambient Temperature (Storage/Transport) -40 °C ... 85 °C
Max. permissible air humidity (service) ≤ 100% (at 25°C, non-condensing)
Radio interference according to EN 55011 EN 55011 (EN 55022) Class B Application in industry and residential
Ambient temperature (Start-Up tested model) -40 °C
Selecting the Right Fuse for Ingress Protection 6 A ... 16 A (US/CAN: branch circuit protection
Radio interference voltage according to EN 55011 EN 55011 (EN 55022) Class B Application in industry and residential
Flammability class according to UL 94 (housing/terminals) V0

Popis produktu

TRIO POWER primary switched power supply in IP67 die casting housing, M12 circular connector, input: single-phase, output: 24 V DC/10 A
Kľúčové vlastnosti
  • Priemyselná kvalita
  • V súlade s RoHS
  • Certifikácia CE
  • 1-ročná záruka

Dokumenty k produktu

Dátový list

Technické špecifikácie a údaje o výkone

Používateľská príručka