Čas služby: pondelok až piatok 9:00-18:00
TRIO-DIODE/12-24DC/2X10/1X20 - TRIO-DIODE/12-24DC/2X10/1X20 2866514 PHOENIX CONTACT Redundancy module
Na sklade Horúci produkt

TRIO-DIODE/12-24DC/2X10/1X20

TRIO-DIODE/12-24DC/2X10/1X20 2866514 PHOENIX CONTACT Redundancy module

$0.00 USD
3245 na sklade
Kľúčové špecifikácie
: 1x 20 A (-25 °C ... 55 °C)
LED: yes
Depth: 115 mm
Input: 2 kV (level 3 - asymmetrical: conductor to ground)
Informácie o dodávateľovi
Produkty: 0
Zvyčajne sa odosiela do 2-3 pracovných dní
Zaručená kvalita
Rýchle doručenie
Technická podpora

Technické špecifikácie

Parameter Hodnota
1x 20 A (-25 °C ... 55 °C)
LED yes
Depth 115 mm
Input 2 kV (level 3 - asymmetrical: conductor to ground)
Shock 15g in all directions in acc. with IEC 60068-2-27
Width 32 mm
Height 130 mm
Output 2 kV (level 3 - asymmetrical: conductor to ground)
Housing Level 3
Voltage 10 V
Comments Criterion B
Derating 55 °C ... 70 °C (2.5 %/K)
Efficiency > 97 %
Input/Output Level 3
Typ produktu Redundancy module
Screw thread M2,5
UL approvals UL/C-UL listed UL 508
Assembly note alignable: horizontally 0 mm, vertically 50 mm
Mounting type DIN rail mounting
Climatic class 3K3 (in acc. with EN 60721)
Product family TRIO DIODE
Status display LED redundancy OK
Frequency range 80 MHz ... 3 GHz
Type of housing Steel sheet, zinc-plated
Article revision 03
Discharge in air 8 kV (Air discharge)
Horizontal pitch 1.8 Div.
Housing material Metal
Protection class III
Stripping length 9 mm
Connection method Screw connection
Contact discharge 6 kV (Contact discharge)
Mounting position horizontal DIN rail NS 35, EN 60715
Output description Contact closed when UIN1& UIN2> 8 V
Types of signaling LED
Degree of pollution 2
Input voltage range 10 V DC ... 30 V DC
Test field strength 10 V/m
Connection in series no
Degree of protection IP20
Maximum current Imax 2x 15 A (-25 °C ... 40 °C)
Side element version Aluminum
Low Voltage Directive Conformance with Low Voltage Directive 2014/35/EC
Standards/regulations EN 61000-4-2
Tightening torque max 0.5 Nm
Vibration (operation)
Input voltage range DC 10 V DC ... 30 V DC
Maximum inrush current ≤ 100 mA (short-circuit-proof)
Nominal output voltage UIn- 0,5 V
Note on status display UIN1& UIN2> 8 V: LED lights up green
Tightening torque, min 0.4 Nm
Maximum switching voltage max. 60 V DC
Standard - Safe isolation DIN VDE 0100-410
MTBF (IEC 61709, SN 29500) > 10000000 h (40 °C)
Nominal input current (IN) 2x 10 A (-25 °C ... 55 °C)
Transient surge protection Varistor
Voltage drop, input/output 0.5 V
Nominal input voltage range 12 V DC ... 24 V DC
Nominal output current (IN) 20 A (Increasing power)
Reverse polarity protection < yes60 V
Power loss nominal load max. 7 W (IOUT= 10 A)
Standard - Electrical safety EN 60950-1/VDE 0805 (SELV)
Electromagnetic compatibility Conformance with EMC Directive 2014/30/EU
Voltage type of supply voltage DC
Ambient temperature (operation) -25 °C ... 70 °C (> 55° C derating : 2.5%/K)
Conductor cross section AWG max. 14
Conductor cross section AWG min. 24
Installation distance right/left 0 mm / 0 mm
Installation distance top/bottom 50 mm / 50 mm
Conductor cross section, rigid max. 2.5 mm²
Conductor cross section, rigid min. 0.2 mm²
EMC requirements for noise emission EN 61000-6-3
EMC requirements for noise immunity EN 61000-6-1
Conductor cross section flexible max. 2.5 mm²
Conductor cross section flexible min. 0.2 mm²
Standard – Safety extra-low voltage IEC 60950-1 (SELV) and EN 60204-1 (PELV)
Ambient temperature (storage/transport) -40 °C ... 85 °C
Insulation voltage input, output / housing 500 V
Max. permissible relative humidity (operation) ≤ 95 % (at 25 °C, non-condensing)
Emitted radio interference in acc. with EN 55011 EN 55011 (EN 55022) Class B, area of application: Industry and residential
Radio interference voltage in acc. with EN 55011 EN 55011 (EN 55022) Class B, area of application: Industry and residential
Standard – Protection against shock currents, basic requirements for protective separation in electrical equipment EN 50178
Standard – Electronic equipment for use in electrical power installations and their assembly into electrical power installations EN 50178/VDE 0160 (PELV)

Popis produktu

Redundancy module with functional monitoring, 12 ... 24 V DC, 2x 10 A, 1x 20 A
Kľúčové vlastnosti
  • Priemyselná kvalita
  • V súlade s RoHS
  • Certifikácia CE
  • 1-ročná záruka

Dokumenty k produktu

Dátový list

Technické špecifikácie a údaje o výkone

Používateľská príručka

Návod na inštaláciu a obsluhu

Top