Čas služby: pondelok až piatok 9:00-18:00
TMC 1 F1 1000,8A - TMC 1 F1 100 0,8A 0914060 PHOENIX CONTACT Switches, protection devices, thermal magnetic, Number of poles: 1..
Na sklade Horúci produkt

TMC 1 F1 1000,8A

TMC 1 F1 100 0,8A 0914060 PHOENIX CONTACT Switches, protection devices, thermal magnetic, Number of poles: 1..

$0.00 USD
4525 na sklade
Kľúčové špecifikácie
: 65 V AC / 1 A (minimum induction)
Fuse: F1 (fast)
Depth: 96 mm
Width: 12.5 mm
Informácie o dodávateľovi
Produkty: 0
Zvyčajne sa odosiela do 2-3 pracovných dní
Zaručená kvalita
Rýchle doručenie
Technická podpora

Technické špecifikácie

Parameter Hodnota
65 V AC / 1 A (minimum induction)
Fuse F1 (fast)
Depth 96 mm
Width 12.5 mm
Height 82.5 mm
Fuse Type Automatic fuse
Shot Type TM (thermomagnetic)
Male Gauge A3
Construction Rail-mounted, one-piece module
Product Type Device protection switches, thermomagnetic
Screw thread M3
Open sidewall No
Article Review 03
Humidity check 240 h, 95% RH, 40°C
Number of rows 2
Product Family TMC
Surge Category Ii
Nominal current 0.8 A
Nominal voltage 65 V DC
Number of poles 1
Dimension Scheme
Protection Index IP30 (Drive Range)
Rated Current IN 0.8 A
Rules/Provisions EN 60934
Type of mounting Symmetrical rail: 35 mm
Tightening torque 0,6 ... 0.8 Nm
Degree of pollution 2
Dielectric Strength 3000 V AC (Drive Range)
Equipment Endurance 2,8 Ω
Insulating material PA66
AWG Conductor Section 24 ... 10 (Converted according to IEC)
Number of connections 4
Rigid conductor section 0.2 mm² ... 6 mm²
Auxiliary current circuit 240 V AC / 1 A (minimum induction)
Insulating material group Ii
Length to be de-insulated 12 mm
Flexible conductor section 0.2 mm² ... 4 mm²
Insulation Resistance RISO > 100 MΩ (500 VDC)
Ambient Temperature (Service) -30 °C ... 60 °C
Dimensioning Transient Voltage 2.5 kV
Maximum state change periodicities 10000 (In 1 x In, inductive)
Short-circuit breakdown capability 2000 A (UL 1077: 65 V DC)
Flammability class according to UL 94 V-2
Short-Circuit Assigned Breakdown Capacity ICn 2500 A (32 V DC)
2 conductors with the same cross-section, rigid 0.2 mm² ... 0.75 mm²
2 conductors with the same cross-section, flexible 0.2 mm² ... 0.75 mm²
Flexible cable section (toe cap with plastic sleeve) 0.25 mm² ... 2.5 mm²
Flexible cable section (toe cap without plastic sleeve) 0.25 mm² ... 4 mm²
2 conductors of equal cross-section, flexible with toe cap, without plastic sleeve 0.25 mm² ... 1 mm²
2 conductors with the same cross-section, flexible with TWIN toe cap with plastic sleeve 0.5 mm² ... 2.5 mm²

Popis produktu

Protection switches for thermomagnetic devices, number of poles: 1, connection type: Screw connection, cross-section: 0.2 mm2- 6 mm2, AWG: 24 - 10, rated current: 0.8 A, fuse type: Automatic fuse, mou
Kľúčové vlastnosti
  • Priemyselná kvalita
  • V súlade s RoHS
  • Certifikácia CE
  • 1-ročná záruka

Dokumenty k produktu

Dátový list

Technické špecifikácie a údaje o výkone

Používateľská príručka

Návod na inštaláciu a obsluhu

Top