Čas služby: pondelok až piatok 9:00-18:00
S-PT-1X2-24DC-1/2" - S-PT-1X2-24DC-1/2" 2882569 PHOENIX CONTACT Surge protection device
Na sklade Horúci produkt

S-PT-1X2-24DC-1/2"

S-PT-1X2-24DC-1/2" 2882569 PHOENIX CONTACT Surge protection device

$0.00 USD
3169 na sklade
Kľúčové špecifikácie
GTIN: 4046356091657
Note: Made to Order (non-returnable)
Orderkey: 2882569
(General): D1 - 1 kA
Informácie o dodávateľovi
Produkty: 0
Zvyčajne sa odosiela do 2-3 pracovných dní
Zaručená kvalita
Rýchle doručenie
Technická podpora

Technické špecifikácie

Parameter Hodnota
GTIN 4046356091657
Note Made to Order (non-returnable)
Orderkey 2882569
(General) D1 - 1 kA
Catalog page Page 101 (C-4-2017)
Packing unit 1 pc
Country of origin DE (Germany)
Custom tariff number 85369010
(Ambient conditions) VDE 0110-1
Altitude (Dimensions) ≤ 2000 m (amsl (above mean sea level))
Rated current (General) 450 mA (55 °C)
Type (Ambient conditions) Screw-in module
Color (Ambient conditions) silver
Depth (Key Commercial Data) 148 mm
Width (Key Commercial Data) 33.5 mm
Height (Key Commercial Data) 33.5 mm
Nominal voltage UN (General) 24 V DC
Residual current IPE (General) ≤ 2 µA
Resistance in series (General) 2.2 Ω ±10 %
Degree of protection (Dimensions) IP67
IEC test classification (General) C1
Screw thread (Protective circuit) M3
Mounting type (Ambient conditions) direct screw connection
Input attenuation aE, sym. (General) typ. 0.5 dB (≤ 1.5 MHz / 50 Ω)
Max. required back-up fuse (General) 500 mA (T)
Weight per Piece (excluding packing) 363.840 g
Housing material (Ambient conditions) Zinc die-cast, surface bronzed and nickel-plated
Response time tA(line-line) (General) ≤ 1 ns
Stripping length (Protective circuit) 6 mm
Connection method (Protective circuit) Screw connection
Response time tA(line-earth) (General) ≤ 100 ns
Tightening torque (Protective circuit) 0.6 Nm
Maximum continuous voltage UC (General) 40 V DC
Direction of action (Ambient conditions) Line-Line & Line-Earth Ground
Impulse durability (line-line) (General) C2 - 10 kV/5 kA
Number of positions (Ambient conditions) 3
Surge protection fault message (General) none
Connection method IN (Protective circuit) Screw terminal blocks
Impulse durability (line-earth) (General) C2 - 10 kV/5 kA
Response time tA (shield-earth) (General) ≤ 100 ns
Connection method OUT (Protective circuit) Connection line
Connection technology (Protective circuit) Screw connection
Standards/specifications (Connection data) IEC 61643-21 2002
Impulse durability (shield-earth) (General) C2 - 10 kV / 5 kA
Residual voltage at In(line-line) (General) ≤ 55 V
Ambient temperature (operation) (Dimensions) -40 °C ... 85 °C
Operating effective current ICat UC (General) ≤ 10 µA
Conductor cross section AWG (Protective circuit) 26 ... 16
Voltage protection level Up(line-line) (General) ≤ 80 V (C2 - 10 kV / 5 kA)
Voltage protection level Up(line-earth) (General) ≤ 450 V (C2 - 10 kV / 5 kA)
Conductor cross section solid (Protective circuit) 0.14 mm² ... 1.5 mm²
Pulse discharge current Iimp(10/350) µs (General) 1 kA
Total discharge current Itotal(8/20) µs (General) 20 kA
Ambient temperature (storage/transport) (Dimensions) -40 °C ... 85 °C
Total discharge current Itotal(10/350) µs (General) 2 kA
Voltage protection level Up(shield-ground) (General) ≤ 600 V (C2 - 10 kV / 5 kA)
Conductor cross section flexible (Protective circuit) 0.14 mm² ... 1.5 mm²
Voltage protection level Upstatic (line-line) (General) ≤ 50 V (C2 - 10 kV / 5 kA)
Cut-off frequency fg (3 dB), sym. in 50 Ohm system (General) typ. 6 MHz
Nominal discharge current In(8/20) µs (line-line) (General) 10 kA
Cut-off frequency fg (3 dB), sym. in 150 Ohm system (General) typ. 2 MHz
Nominal discharge current In(8/20) µs (line-earth) (General) 10 kA (per path)
Nominal pulse current Ian (10/1000) µs (line-line) (General) 23 A
Residual voltage with Ian (10/1000) µs (line-line) (General) ≤ 65 V
Nominal pulse current Ian (10/1000) µs (line-earth) (General) 100 A
Nominal discharge current In(8/20) µs (shield-earth) (General) 10 kA (optional)
Nominal pulse current Ian (10/1000) µs (Shield-Earth) (General) 100 A
Output voltage limitation at 1 kV/µs (line-line) spike (General) ≤ 55 V
Output voltage limitation at 1 kV/µs (line-earth) spike (General) ≤ 450 V (Direct grounding)
Output voltage limitation at 1 kV/µs (line-line) static (General) ≤ 55 V
Max. discharge current Imax(8/20) µs maximum (line-line) (General) 10 kA
Output voltage limitation at 1 kV/µs (line-earth) static (General) ≤ 450 V (Direct grounding)
Standards for cearances and creepage distances (Ambient conditions) IEC 60664-1
Max. discharge current Imax(8/20) µs maximum (line-earth) (General) 10 kA (per path)
Output voltage limitation at 1 kV/µs (shield-earth) spike (General) ≤ 600 V (optional)
Max. discharge current Imax(8/20) µs maximum (shield-earth) (General) 10 kA

Popis produktu

Overvoltage protection. in IP67 screw-on module for measuring probes, direct mounting via 1/2'' NPT ext. thread, cable gland for signal line, protective circuit. two levels. Suitable for HAR
Kľúčové vlastnosti
  • Priemyselná kvalita
  • V súlade s RoHS
  • Certifikácia CE
  • 1-ročná záruka

Dokumenty k produktu

Dátový list

Technické špecifikácie a údaje o výkone

Používateľská príručka

Návod na inštaláciu a obsluhu