Čas služby: pondelok až piatok 9:00-18:00
PT-IQ-2X2-12DC-PT - PT-IQ-2X2-12DC-PT 2801261 PHOENIX CONTACT Surge protection device
Na sklade Horúci produkt

PT-IQ-2X2-12DC-PT

PT-IQ-2X2-12DC-PT 2801261 PHOENIX CONTACT Surge protection device

$0.00 USD
3522 na sklade
Kľúčové špecifikácie
: C2
Note: Remote signaling as well as the power supply of the DIN rail connector are established by snapping the module into place on the DIN rail connector.
Type: DIN rail module, two-section, divisible
Depth: 77.5 mm (incl. DIN rail 7.5 mm)
Informácie o dodávateľovi
Produkty: 0
Zvyčajne sa odosiela do 2-3 pracovných dní
Zaručená kvalita
Rýchle doručenie
Technická podpora

Technické špecifikácie

Parameter Hodnota
C2
Note Remote signaling as well as the power supply of the DIN rail connector are established by snapping the module into place on the DIN rail connector.
Type DIN rail module, two-section, divisible
Depth 77.5 mm (incl. DIN rail 7.5 mm)
Width 17.7 mm
Height 109.3 mm
Altitude ≤ 4000 m (amsl)
Typ produktu Surge protection for MCR technology
Mounting type DIN rail: 35 mm
Rated current 700 mA (50 °C)
Product family PLUGTRAB IQ
Open side panel No
Horizontal pitch 1 Div.
Housing material PA 6.6
Pollution degree 2
Connection method Push-in connection
Nominal voltage UN 12 V DC
Dimensional drawing
Direction of action Line-Line & Line-Signal Ground/Shield & optional Signal Ground/Shield-Earth Ground
Resistance per path 1.2 Ω ±5 %
Capacity (Core-Core) typ. 4 nF
Degree of protection IP20
Overvoltage category III
Residual current IPE ≤ 2 µA (per signal circuit)
Wire pairs per module 2
IEC test classification C1
Standards/specifications IEC 61643-21
Input attenuation aE, sym. typ. 0.3 dB (≤ 95 kHz/150 Ω)
Max. required back-up fuse 800 mA (FF)
Conductor cross section AWG 24 ... 12
Response time tA(line-line) ≤ 1 ns
Pulse reset time (line-line) ≤ 25 ms
Response time tA(line-earth) ≤ 100 ns
Conductor cross section rigid 0.2 mm² ... 4 mm²
Maximum continuous voltage UC 15 V DC
Pulse reset time (line-earth) ≤ 50 ms
Impulse durability (line-line) C1 - 1 kV / 500 A
Surge protection fault message Optical, multi-stage
Ambient temperature (operation) -40 °C ... 70 °C
Impulse durability (line-earth) C1 - 1 kV / 500 A
Conductor cross section flexible 0.2 mm² ... 2.5 mm²
Operating effective current ICat UC ≤ 1 µA (in the signal circuit)
Flammability rating according to UL 94 V-0
Voltage protection level Up(line-line) ≤ 65 V (C1 - 1 kV / 500 A)
Ambient temperature (storage/transport) -40 °C ... 85 °C
Voltage protection level Up(line-earth) ≤ 600 V (C1 - 1 kV / 500 A)
Total discharge current Itotal(8/20) µs 20 kA
Voltage protection level Upstatic (line-line) ≤ 45 V (C1 - 1 kV / 500 A)
Nominal discharge current In(8/20) µs (line-line) 10 kA
Cut-off frequency fg (3 dB), sym. in 150 Ω system typ. 600 kHz
Nominal discharge current In(8/20) µs (line-ground) 10 kA
Pulse discharge current Iimp(10/350) µs (line-earth) 2.5 kA

Popis produktu

Surge protection, consisting of protective plug and base element, with integrated multi-stage status indicator on the module for two 2-wire floating signal circuits. Can be used in safety-related circ
Kľúčové vlastnosti
  • Priemyselná kvalita
  • V súlade s RoHS
  • Certifikácia CE
  • 1-ročná záruka

Dokumenty k produktu

Dátový list

Technické špecifikácie a údaje o výkone

Používateľská príručka

Návod na inštaláciu a obsluhu

Top