Čas služby: pondelok až piatok 9:00-18:00
PT-IQ-1X2+F-24DC-UT - PT-IQ-1X2+F-24DC-UT 2800977 PHOENIX CONTACT Surge protection device
Na sklade Horúci produkt

PT-IQ-1X2+F-24DC-UT

PT-IQ-1X2+F-24DC-UT 2800977 PHOENIX CONTACT Surge protection device

$0.00 USD
4344 na sklade
Kľúčové špecifikácie
: C2
Note: Remote signaling as well as the power supply of the DIN rail connector are established by snapping the module into place on the DIN rail connector.
Type: DIN rail module, two-section, divisible
Color: black (RAL 9005)
Informácie o dodávateľovi
Produkty: 0
Zvyčajne sa odosiela do 2-3 pracovných dní
Zaručená kvalita
Rýchle doručenie
Technická podpora

Technické špecifikácie

Parameter Hodnota
C2
Note Remote signaling as well as the power supply of the DIN rail connector are established by snapping the module into place on the DIN rail connector.
Type DIN rail module, two-section, divisible
Color black (RAL 9005)
Depth 77.5 mm (incl. DIN rail 7.5 mm)
Width 17.7 mm
Height 91.1 mm
Altitude ≤ 4000 m (amsl)
Typ produktu Surge protection for MCR technology
Screw thread M3
Mounting type DIN rail: 35 mm
Rated current 1000 mA (40 °C)
Product family PLUGTRAB IQ
Open side panel No
Article revision 08
Horizontal pitch 1 Div.
Housing material PA 6.6
Pollution degree 2
Connection method Screw connection
Tightening torque 0.5 Nm
Nominal voltage UN 24 V DC
Dimensional drawing
Direction of action Line-Line & Line-Signal Ground/Shield & optional Signal Ground/Shield-Earth Ground
Resistance per path 1.2 Ω ±5 %
Degree of protection IP20
Overvoltage category III
Residual current IPE ≤ 1 µA
Capacity (Core-Earth) typ. 2 nF
Wire pairs per module 1
IEC test classification C1
Standards/specifications IEC 61643-21
Input attenuation aE, sym. typ. 0.3 dB (≤ 270 kHz/150 Ω)
Max. required back-up fuse 1 A (FF)
Conductor cross section AWG 24 ... 12
Response time tA(line-line) ≤ 1 ns
Pulse reset time (line-line) ≤ 4000 ms
Response time tA(line-earth) ≤ 100 ns
Conductor cross section rigid 0.2 mm² ... 4 mm²
Maximum continuous voltage UC 30 V DC
Pulse reset time (line-earth) ≤ 30 ms
Impulse durability (line-line) C1 - 1 kV / 500 A
Surge protection fault message Optical, multi-stage
Ambient temperature (operation) -40 °C ... 70 °C
Impulse durability (line-earth) C1 - 1 kV / 500 A
Conductor cross section flexible 0.2 mm² ... 2.5 mm²
Permissible humidity (operation) 5 % ... 95 %
Operating effective current ICat UC ≤ 1 mA (in the signal circuit)
Response time tA(line-signalground) ≤ 100 ns
Pulse reset time (line-signalground) ≤ 2600 ms
Flammability rating according to UL 94 V-0
Impulse durability (line-signalground) C1 - 1 kV / 500 A
Voltage protection level Up(line-line) ≤ 80 V (C1 - 1 kV / 500 A)
Ambient temperature (storage/transport) -40 °C ... 85 °C
Voltage protection level Up(line-earth) ≤ 900 V (C1 - 1 kV / 500 A)
Total discharge current Itotal(8/20) µs 20 kA
Voltage protection level Upstatic (line-line) ≤ 65 V (C1 - 1 kV / 500 A)
Voltage protection level Up(line-signalground) ≤ 600 V (C1 - 1 kV / 500 A)
Nominal discharge current In(8/20) µs (line-line) 10 kA
Cut-off frequency fg (3 dB), sym. in 150 Ω system typ. 1.1 MHz
Nominal discharge current In(8/20) µs (line-ground) 10 kA
Pulse discharge current Iimp(10/350) µs (line-earth) 2.5 kA

Popis produktu

Surge protection, consisting of plug-in protection and base element, with multi-level diagnostic and status indication integrated into a module for a circ. of 2-wire signal free of potential. Indir gr
Kľúčové vlastnosti
  • Priemyselná kvalita
  • V súlade s RoHS
  • Certifikácia CE
  • 1-ročná záruka

Dokumenty k produktu

Dátový list

Technické špecifikácie a údaje o výkone

Používateľská príručka

Návod na inštaláciu a obsluhu

Top