Kľúčové špecifikácie
: Machine building
Note: The maximum load current of a single clamping unit must not be exceeded.
Color: gray
Width: 5.2 mm
Informácie o dodávateľovi
Produkty: 0
Zvyčajne sa odosiela do 2-3 pracovných dní
Zaručená kvalita
Rýchle doručenie
Technická podpora

Technické špecifikácie

Parameter Hodnota
Machine building
Note The maximum load current of a single clamping unit must not be exceeded.
Color gray
Width 5.2 mm
Height 142.4 mm
Result Test passed
Spectrum Service life test category 1, class B, body mounted
ASD level 0.964 (m/s²)²/Hz
Frequency f1= 5 Hz to f2= 150 Hz
Potentials 4
Pulse shape Half-sine
Revolutions 135
Acceleration 0.58g
Typ produktu Multi-level terminal block
Mounting type NS 35/7,5
Specification DIN EN 50155 (VDE 0115-200):2022-06
Number of rows 4
Rotation speed 10 rpm
Shock duration 30 ms
End cover width 2.2 mm
Nominal current 18 A
Nominal voltage 500 V
Open side panel Yes
Test directions X-, Y- and Z-axis
Stripping length 8 mm ... 10 mm
Time of exposure 30 s
Cross section AWG (converted acc. to IEC)
Depth on NS 35/15 76.1 mm
Temperature cycles 192
Area of application Railway industry
Degree of pollution 3
Depth on NS 35/7,5 68.6 mm
Insulating material PA
Number of positions 4
Rated surge voltage 6 kV
Maximum load current 20 A (with 4 mm² conductor cross-section)
Overvoltage category III
Nominal cross section 2.5 mm²
Number of connections 8
Test voltage setpoint 1.89 kV
Test duration per axis 5 h
Insulating material group I
Internal cylindrical gage A3
Conductor cross section rigid 0.14 mm² ... 4 mm²
Ambient temperature (assembly) -5 °C ... 70 °C
Conductor cross section/weight 0.14 mm² / 0.2 kg
Number of shocks per direction 3
Ambient temperature (actuation) -5 °C ... 70 °C
Ambient temperature (operation) -60 °C ... 105 °C (max. short-term operating temperature RTI Elec.)
Number of connections per level 2
Conductor cross section flexible 0.14 mm² ... 4 mm²
Connection in acc. with standard IEC 60947-7-1
Requirement temperature-rise test Increase in temperature ≤ 45 K
Conductor cross section, rigid [AWG] 20 ... 12 (converted acc. to IEC)
Short-time withstand current 2.5 mm² 0.3 kA
Flammability rating according to UL 94 V0
Smoke gas toxicity NFPA 130 (SMP 800C) passed
Ambient temperature (storage/transport) -25 °C ... 60 °C (for a short time, not exceeding 24 h, -60 °C to +70 °C)
Conductor cross section, flexible [AWG] 26 ... 12 (converted acc. to IEC)
Permissible humidity (storage/transport) 30 % ... 70 %
Surface flammability NFPA 130 (ASTM E 162) passed
Static insulating material application in cold -60 °C
Maximum power dissipation for nominal condition 0.77 W
Fire protection for rail vehicles (DIN EN 45545-2) R22 HL 1 - HL 3
Fire protection for rail vehicles (DIN EN 45545-2) R23 HL 1 - HL 3
Fire protection for rail vehicles (DIN EN 45545-2) R24 HL 1 - HL 3
Fire protection for rail vehicles (DIN EN 45545-2) R26 HL 1 - HL 3
Specific optical density of smoke NFPA 130 (ASTM E 662) passed
Flexible conductor cross section (ferrule with plastic sleeve) 0.14 mm² ... 2.5 mm²
Relative insulation material temperature index (Elec., UL 746 B) 130 °C
Conductor cross-section flexible (ferrule without plastic sleeve) 0.14 mm² ... 2.5 mm²

Popis produktu

Multi-level terminal block, nom. voltage: 500 V, nominal current: 18 A, connection method: Push-in connection, Rated cross section: 2.5 mm2, cross section: 0.14 mm2 - 4 mm2, mounting type: NS 35/7,5,
Kľúčové vlastnosti
  • Priemyselná kvalita
  • V súlade s RoHS
  • Certifikácia CE
  • 1-ročná záruka

Dokumenty k produktu

Dátový list

Technické špecifikácie a údaje o výkone

Používateľská príručka

Návod na inštaláciu a obsluhu

Top