Čas služby: pondelok až piatok 9:00-18:00
PSR-SCF-24UC/URM/4X1/2X2 - PSR-SCF- 24UC/URM/4X1/2X2 2981444 PHOENIX CONTACT Coupling relay
Na sklade Horúci produkt

PSR-SCF-24UC/URM/4X1/2X2

PSR-SCF- 24UC/URM/4X1/2X2 2981444 PHOENIX CONTACT Coupling relay

$0.00 USD
3029 na sklade
Kľúčové špecifikácie
GTIN: 4017918987787
Orderkey: 2981444
Catalog page: Page 279 (C-6-2017)
Depth (Note): 55 mm
Informácie o dodávateľovi
Produkty: 0
Zvyčajne sa odosiela do 2-3 pracovných dní
Zaručená kvalita
Rýchle doručenie
Technická podpora

Technické špecifikácie

Parameter Hodnota
GTIN 4017918987787
Orderkey 2981444
Catalog page Page 279 (C-6-2017)
Depth (Note) 55 mm
Packing unit 1 pc
Width (Note) 40 mm
(Input data) 6 A gL/gG (N/C contact)
Height (Note) 111 mm
Country of origin DE (Germany)
pluggable (General) no
Custom tariff number 85364900
Screw thread (General) M3
Net weight (Output data) 127 g
Output fuse (Input data) 10 A gL/gG (N/O contact)
Relay type (Output data) Electromechanical relay with forcibly guided contacts in accordance with EN 50205
Contact type (Input data) 4 enabling current paths
Category (Connection data) 1
Stripping length (General) 7 mm
Connection method (General) Screw connection
Housing color (Output data) green
Mounting type (Output data) DIN rail mounting
(Standards and Regulations) For details about hazardous substances go to tab “Downloads”, Category “Manufacturer's declaration”
Contact material (Input data) AgSnO2
Designation (Connection data) EN ISO 13849
Maximum altitude (Dimensions) ≤ 2000 m (Above sea level)
Housing material (Output data) PBT
Sq. Total current (Input data) 72 A2
Mounting position (Output data) vertical or horizontal
Stop category (Connection data) 0
Switching capacity (Input data) min. 50 mW
Degree of protection (Output data) IP20
Recovery time (Ambient conditions) < 500 ms
Maximum inrush current (Input data) 6 A
Inrush current, minimum (Input data) 10 mA
Mechanical service life (Input data) 10x 106cycles
Nominal operating mode (Output data) 100% operating factor
Weight per Piece (excluding packing) 127.000 g
(Safety-related characteristic data) Basic insulation 4 kV between all output current paths
China RoHS (Standards and Regulations) Environmentally Friendly Use Period = 50
Maximum switching voltage (Input data) 230 V AC/DC (Observe the load curve)
Minimum switching voltage (Input data) 5 V AC/DC
REACh SVHC (Standards and Regulations) Lead 7439-92-1
Limiting continuous current (Input data) 6 A
Performance level (PL) (Connection data) c
Typical release time (Ambient conditions) typ. 10 ms (when controlled via A1)
Conductor cross section AWG max. (General) 12
Conductor cross section AWG min. (General) 24
Shock (Safety-related characteristic data) 15g (In the event of stress caused by shock, contact reactions are possible for up to 2 ms.)
Ambient temperature (operation) (Dimensions) -20 °C ... 55 °C
Conductor cross section solid max. (General) 2.5 mm²
Conductor cross section solid min. (General) 0.2 mm²
Power consumption at US (Ambient conditions) typ. 1.25 W
Utilization restriction (Key Commercial Data) 1
Operating voltage display (Ambient conditions) 1 x green LED
Safety Integrity Level (SIL) (Connection data) 1
Conductor cross section flexible max. (General) 2.5 mm²
Conductor cross section flexible min. (General) 0.2 mm²
Typ. starting time with Us (Ambient conditions) typ. 10 ms (when controlled via A1)
Conformance (Safety-related characteristic data) CE-compliant
Designation (Safety-related characteristic data) Air clearances and creepage distances between the power circuits
Maximum switching frequency (Ambient conditions) 0.5 Hz
Interrupting rating (ohmic load) max. (Input data) For additional values, see load curve
Ambient temperature (storage/transport) (Dimensions) -40 °C ... 85 °C
Rated control supply current IS (Ambient conditions) typ. 52 mA
Degree of pollution (Safety-related characteristic data) 2
Maximum interrupting rating (inductive load) (Input data) 48 W (N/O contact, 24 V DC, τ = 40 ms)
Min. degree of protection of inst. location (Output data) IP54
Overvoltage category (Safety-related characteristic data) III
Max. permissible humidity (storage/transport) (Dimensions) 75 % (on average, 85% infrequently, non-condensing)
Standards/regulations (Safety-related characteristic data) DIN EN 50178
Switching capacity according to IEC 60947-5-1 (Input data) 5 A (24 V (DC13))
Vibration (operation) (Safety-related characteristic data) 10 Hz ... 150 Hz, 2g (In the event of stress caused by vibration, contact reactions are possible for up to 2 ms.)
Max. permissible relative humidity (operation) (Dimensions) 75 % (on average, 85% infrequently, non-condensing)
Rated control circuit supply voltage US (Ambient conditions) 24 V AC/DC -20 % / +10 %
Rated insulation voltage (Safety-related characteristic data) 250 V
Safety Integrity Level Claim Limit (SIL CL) (Connection data) 1
Rated surge voltage/insulation (Safety-related characteristic data) Safe isolation, reinforced insulation 6 kV between input circuit (A1/A2) and all output current paths

Popis produktu

Secure coupling relay with forced-conduction contacts, 4 normally open contacts, 2 normally closed contacts, fixed screw terminal, width: 40 mm
Kľúčové vlastnosti
  • Priemyselná kvalita
  • V súlade s RoHS
  • Certifikácia CE
  • 1-ročná záruka

Dokumenty k produktu

Dátový list

Technické špecifikácie a údaje o výkone

Používateľská príručka

Návod na inštaláciu a obsluhu

Top