: Safe isolation, reinforced insulation 6 kV between 250 V load current paths and 24 V logic paths
Depth: 104 mm
Shock: 10g for Δt = 11 ms (continuous shock: 5g for Δt = 16 ms)
Width: 14 mm
Informácie o dodávateľovi
Produkty: 0
Zvyčajne sa odosiela do 2-3 pracovných dní
Zaručená kvalita
Rýchle doručenie
Technická podpora

Technické špecifikácie

Parameter Hodnota
Safe isolation, reinforced insulation 6 kV between 250 V load current paths and 24 V logic paths
Depth 104 mm
Shock 10g for Δt = 11 ms (continuous shock: 5g for Δt = 16 ms)
Width 14 mm
Height 80 mm
Category 1
Relay type Electromechanical relay in accordance with IEC/EN 61810
Application Forcibly guided contacts
Designation A1/A2
Filter time 1 ms (Test pulse width, high test pulse and low test pulse)
Output fuse 6 A gL/gG
Typ produktu Coupling relay
Mounting type DIN rail mounting
Recovery time 500 ms (following demand of the safety function)
Identification CE-compliant
Inrush current typ. 100 mA (Δt = 10 ms at Us)
Product family PLC-INTERFACE
Status display 1 x green LED (PWR)
Contact material AgNi
Housing material Polyamide
Maximum altitude ≤ 2000 m (Above sea level)
Pollution degree 2
Stripping length 8 mm
Connection method Push-in connection
Mounting position vertical or horizontal
Number of outputs 2
Sq. Total current 37 A2(N/O contact, high-demand, observe derating)
Output description safety-related
Protective circuit Serial protection against polarity reversal; Suppressor diode, 38.6 V/600 W
Switching capacity min. 150 mW (N/O contact / N/C contact)
Switching frequency max. 1 Hz
Degree of protection IP20
Overvoltage category III
Typical release time < 50 ms (on demand via A1)
Assembly instructions See derating curve
Standards/regulations IEC 60947-1
Vibration (operation) 10 Hz ... 150 Hz, amplitude 0.75 mm, 1g
Contact switching type 2 changeover contacts
Nominal operating mode 100% operating factor
Performance level (PL) c
Mechanical service life approx. 107cycles
Power consumption at UD 650 mW (to US)
Rated insulation voltage 250 V AC
Operating voltage display 1 x green LED (PWR)
Typ. starting time with Us < 70 ms (when controlled via A1)
Conductor cross-section AWG 26 ... 14
Limiting continuous current 6 A (N/O contact, high demand)
Safety Integrity Level (SIL) 2
Conductor cross section rigid 0.14 mm² ... 2.5 mm²
Rated surge voltage/insulation Basic insulation 4 kV between all current paths and housing
Ambient temperature (operation) -20 °C ... 60 °C (observe derating)
Rated control supply current IS 30 mA
Conductor cross section flexible 0.14 mm² ... 2.5 mm²
Ambient temperature (storage/transport) -20 °C ... 85 °C
Rated control circuit supply voltage US 21.6 V DC ... 28.8 V DC
Min. degree of protection of inst. location IP54
Max. permissible humidity (storage/transport) 75 % (on average; 95% occasionally, non-condensing)
Max. permissible relative humidity (operation) 75 % (on average; 95% occasionally, non-condensing)
Maximum power dissipation for nominal condition 4.825 W (UB= 30 V, US= 24 V, IS= 30 mA, IL² = 37 A, Rcontact= 0.1 Ω)
Switching capacity in accordance with IEC 60947-5-1 6 A (AC1, 230 V)
Conductor cross section flexible, with ferrule without plastic sleeve 0.2 mm² ... 2.5 mm²