Kľúčové špecifikácie
: 60 V DC
Type: Plug angled M12
Coding: X
Damping: 3.1 dB (with 1 MHz)
Informácie o dodávateľovi
Produkty: 0
Zvyčajne sa odosiela do 2-3 pracovných dní
Zaručená kvalita
Rýchle doručenie
Technická podpora

Technické špecifikácie

Parameter Hodnota
60 V DC
Type Plug angled M12
Coding X
Damping 3.1 dB (with 1 MHz)
Material CuZn (Contact)
Shielded yes
Shielding Tinned copper braided shield
Cable type Ethernet 10 Gbit
Coding type X (Data)
Sensor type Ethernet
Cable length 2 m
Cable weight 42 kg/km
Halogen-free according to IEC 60754-1
Typ produktu Data cable preassembled
Short symbol 02YSC11Y
UL AWM Style 20963 (80°C/30 V)
Overall twist 4 pairs for core
Twisted pairs 2 cores to the pair
Cable capacity 47 nF/km
Signal runtime 5.13 ns/m
Wave impedance 100 Ω ±5 Ω (at 100 MHz)
AWG signal line 26
Cable structure 4x2xAWG26/7; S/FTP
Loop resistance ≤ 290.00 Ω/km
Flame resistance according to IEC 60332-1-2
Tensile strength ≤ 100 N
Resistance to oil in accordance with DIN EN 60811-2-1
Conductor material Bare Cu litz wires
Nominal current IN 0.5 A
Nominal voltage UN 48 V AC
Shield attenuation ≥ 80 dB (at 30 ... 100 MHz)
Single wire, color white/blue-blue, white/orange-orange, white/green-green, white/brown-brown
Dimensional drawing
Number of positions 8
Degree of protection IP20
No. of cable outlets 1
Signal type/category Ethernet CAT6A
External sheath, color water blue RAL 5021
Nominal voltage, cable ≤ 100 V
Outer sheath, material PUR
Test voltage Core/Core 700 V (50 Hz, 1 min.)
Type of pair shielding Aluminum-lined foil
Conductor cross section 4x 2x 0.14 mm²
External cable diameter 6.4 mm ±0.2 mm
Optical shield covering 70 %
Return attenuation (RL) 20 dB (with 1 MHz)
Thickness, outer sheath 0.65 mm
Material wire insulation Foamed PE
Test voltage Core/Shield 700 V (50 Hz, 1 min.)
Cable type (abbreviation) 94F
Cable insulation resistance ≥ 500 MΩ*km
Wire diameter incl. insulation 1.04 mm
Ambient temperature (operation) -20 °C ... 80 °C (Cable, flexible installation)
Conductor structure signal line 7x 0.16 mm
Near end crosstalk attenuation (NEXT) 75.3 dB (with 1 MHz)
Transmission characteristics (category) CAT6A
Minimum bending radius, fixed installation 4 x D
Minimum bending radius, flexible installation 8 x D
Power-summated near end crosstalk attenuation (PSNEXT) 72.3 dB (with 1 MHz)

Popis produktu

Network cable
Kľúčové vlastnosti
  • Priemyselná kvalita
  • V súlade s RoHS
  • Certifikácia CE
  • 1-ročná záruka

Dokumenty k produktu

Dátový list

Technické špecifikácie a údaje o výkone

Používateľská príručka

Návod na inštaláciu a obsluhu