MNT-TAE D - MNT-TAE D 2882381 PHOENIX CONTACT Type 3 surge protection device
Na sklade Horúci produkt

MNT-TAE D

MNT-TAE D 2882381 PHOENIX CONTACT Type 3 surge protection device

$0.00 USD
4294 na sklade
Kľúčové špecifikácie
GTIN: 4046356073455
Orderkey: 2882381
Catalog page: Page 74 (C-4-2017)
Packing unit: 1 pc
Informácie o dodávateľovi
Produkty: 0
Zvyčajne sa odosiela do 2-3 pracovných dní
Zaručená kvalita
Rýchle doručenie
Technická podpora

Technické špecifikácie

Parameter Hodnota
GTIN 4046356073455
Orderkey 2882381
Catalog page Page 74 (C-4-2017)
Packing unit 1 pc
Country of origin DE (Germany)
EN type (General) T3
Custom tariff number 85363010
Type (Ambient conditions) Attachment plug
Color (Ambient conditions) jet black RAL 9005
Depth (Key Commercial Data) 78 mm
Width (Key Commercial Data) 63 mm
Height (Key Commercial Data) 103 mm
Nominal voltage UN (General) 230 V AC
Response time (L-N) (General) ≤ 25 ns
Combination wave UOC (General) 4 kV
Nominal frequency fN (General) 50 Hz (60 Hz)
Residual current IPE (General) ≤ 5 µA
Response time (L-PE) (General) ≤ 100 ns
Response time (N-PE) (General) ≤ 100 ns
Rated load current IL (General) 16 A (30 °C)
Mounting type (Ambient conditions) Plugging into the mains socket
Max. required back-up fuse (General) 16 A (gG / B / C)
Weight per Piece (excluding packing) 194.000 g
Housing material (Ambient conditions) PA 6
Standby power consumption PC (General) ≤ 1 VA
Energy absorption symmetrical (General) 140 J (L-N)
Arrester rated voltage UC(L-N) (General) 275 V AC
Direction of action (Ambient conditions) L/N-PE & Signal Line-Earth Ground
Enery absorption, asymmetrical (General) 220 J (L(N)-PE)
Surge protection fault message (General) optical
Arrester rated voltage UC(L-PE) (General) 360 V AC
Arrester rated voltage UC(N-PE) (General) 360 V AC
Connection method (Power supply, general) Via protective contact plug
Voltage protection level Up(L-N) (General) ≤ 1.2 kV
Voltage protection level Up(L-PE) (General) ≤ 1.5 kV
Voltage protection level Up(N-PE) (General) ≤ 1.5 kV
Ambient temperature (operation) (Dimensions) -25 °C ... 75 °C
(Connection (protective circuit, power supply)) D1 - 500 A
For country-specific use in (Ambient conditions) D
Nominal discharge current In(8/20) µs (General) 3 kA (> 5x)
Ambient temperature (storage/transport) (Dimensions) -25 °C ... 75 °C
Connection method (Protective circuit, power supply) Grounding plug/socket
Connection method IN (Protective circuit, power supply) Grounding plug
Connection method OUT (Protective circuit, power supply) Grounding socket
Flammability rating according to UL 94 (Ambient conditions) V-0
(Connection, equipotential bonding, information technology) D1
Rated current (Connection (protective circuit, power supply)) 150 mA (25 °C)
Connection method (Protective circuit, information technology) RJ12-/TAE 6
Connection method IN (Protective circuit, information technology) RJ12 female connector
Connection method OUT (Protective circuit, information technology) TAE 6 socket
Capacity (line-line) (Connection (protective circuit, power supply)) typ. 1 nF
Residual current IPE (Connection (protective circuit, power supply)) ≤ 2 µA
Capacity (line-earth) (Connection (protective circuit, power supply)) typ. 5 pF
Arrester rated voltage UC (Connection (protective circuit, power supply)) 200 V DC
Insulation resistance Riso (Connection (protective circuit, power supply)) ≥ 1 MΩ
Response time tA(line-line) (Connection (protective circuit, power supply)) ≤ 25 ns
Pulse reset time (line-line) (Connection (protective circuit, power supply)) ≤ 15 ms
Response time tA(line-earth) (Connection (protective circuit, power supply)) ≤ 100 ns
Impulse durability (line-line) (Connection (protective circuit, power supply)) C2 - 2 kV / 1 kA
Impulse durability (line-earth) (Connection (protective circuit, power supply)) C2 - 4 kV/2 kA
Residual voltage at In(line-line) (Connection (protective circuit, power supply)) ≤ 500 V
Residual voltage at In(line-earth) (Connection (protective circuit, power supply)) ≤ 30 V
IEC test classification (Connection, equipotential bonding, information technology) C1
Operating effective current ICat UC (Connection (protective circuit, power supply)) ≤ 150 µA
Max. discharge current Imax(8/20) µs (Connection (protective circuit, power supply)) 2.5 kA
Voltage protection level Up(line-line) (Connection (protective circuit, power supply)) ≤ 460 V (C2 - 1 kA)
Voltage protection level Up(line-earth) (Connection (protective circuit, power supply)) ≤ 900 V (C2 - 2 kA)
Alternating current carrying capacity (line-line) (Connection (protective circuit, power supply)) 250 mA - 1 s
Output voltage limitation at 1 kV/µs (wire-wire) (Connection (protective circuit, power supply)) ≤ 360 V
Alternating current carrying capacity (line-earth) (Connection (protective circuit, power supply)) 10 A - 1 s
Nominal discharge current In(8/20) µs (line-line) (Connection (protective circuit, power supply)) 1 kA
Cut-off frequency fg (3 dB), sym. in 100 Ohm system (Connection (protective circuit, power supply)) typ. 4 MHz
Cut-off frequency fg (3 dB), sym. in 150 Ohm system (Connection (protective circuit, power supply)) typ. 3 MHz
Cut-off frequency fg (3 dB), sym. in 600 Ohm system (Connection (protective circuit, power supply)) typ. 700 kHz
Nominal discharge current In(8/20) µs (line-earth) (Connection (protective circuit, power supply)) 2.5 kA
Residual voltage with Ian (10/1000) µs (line-line) (Connection (protective circuit, power supply)) ≤ 35 V
Residual voltage with Ian (10/1000) µs (line-earth) (Connection (protective circuit, power supply)) ≤ 35 V

Popis produktu

Intermediate socket connector with surge protection for the power supply and signal connection of a terminal equipment with analogue or digital telecommunication interface (VDSL up to 50 Mbit/s) in sh
Kľúčové vlastnosti
  • Priemyselná kvalita
  • V súlade s RoHS
  • Certifikácia CE
  • 1-ročná záruka

Dokumenty k produktu

Dátový list

Technické špecifikácie a údaje o výkone

Používateľská príručka

Návod na inštaláciu a obsluhu

Top