Parameter Hodnota
GTIN 4046356043632
Note Made to Order (non-returnable)
Orderkey 2813457
Catalog page Page 247 (C-5-2017)
Packing unit 1 pc
(Input data) 0 V ... 5 V
Country of origin JP (Japan)
Custom tariff number 85437090
Conformance (General) CE-compliant
Color (Connection data) green
Output name (Input data) Voltage output
Torque (Connection data) 0.5 Nm ... 0.6 Nm (4,4 ... 5,31 lbf-in.)
UL, USA/Canada (General) UL/C-UL listed UL 508
Output name (Output data) No switching output
Input (Ambient conditions) Current measuring input
Depth (Key Commercial Data) 70.5 mm
Screw thread (Power supply) M3
Width (Key Commercial Data) 55 mm
(Standards and Regulations) For details about hazardous substances go to tab “Downloads”, Category “Manufacturer's declaration”
Height (Key Commercial Data) 85 mm
Conformance (Connection data) CE-compliant
Stripping length (Power supply) 8 mm
Connection method (Power supply) Pluggable screw connection
Max. output voltage (Input data) (0 V ... 10 V) 14 V, (0 V ... 5 V) 7 V
UL, USA/Canada (Connection data) UL/C-UL listed UL 508
Housing material (Connection data) Polyamide PA non-reinforced
Voltage output signal (Input data) 0 V ... 10 V
Mounting position (Connection data) any
Surge strength (Ambient conditions) Depending on through connected conductor
Weight per Piece (excluding packing) 137.100 g
Degree of pollution (Connection data) 2
China RoHS (Standards and Regulations) Environmentally Friendly Use Period = 25;
Operate threshold (Ambient conditions) 1 % (of final value)
Overload capacity (Ambient conditions) Depending on laid conductor
Overvoltage category (Connection data) III
Supply voltage range (Switching output) 20 V DC ... 30 V DC
Input current range (Ambient conditions) 0 A ... 100 A (0 ... 50/75/100 A)
Step response (10-90%) (Connection data) < 340 ms
Rated insulation voltage (Connection data) 300 V AC (to earth)
Max. current consumption (Switching output) < 30 mA
Test voltage input/output (Connection data) 5 kV (50 Hz, 1 min.)
Ambient temperature (operation) (Dimensions) -20 °C ... 60 °C
Load/output load voltage output (Input data) ≥ 10 kΩ
Maximum transmission error (Connection data) < 1 % (of final value)
Frequency measuring range (Ambient conditions) 30 Hz ... 6000 Hz
Conductor cross section AWG max. (Power supply) 14
Conductor cross section AWG min. (Power supply) 24
Conductor cross section solid max. (Power supply) 2.5 mm²
Conductor cross section solid min. (Power supply) 0.2 mm²
Maximum temperature coefficient (Connection data) < 0.035 %/K
Conductor cross section flexible max. (Power supply) 2.5 mm²
Conductor cross section flexible min. (Power supply) 0.2 mm²
Primary round conductor (diameter) (Key Commercial Data) 18.5 mm
Setting range for max. input current (Ambient conditions) 0 A ... 100 A
Setting range for min. input current (Ambient conditions) 0 A ... 50 A

Popis produktu

MCR current converter, for measuring sinusoidal and non-sinusoidal alternating currents, input current 0...100 A, output voltage 0... (5) 10 V
Kľúčové vlastnosti
  • Priemyselná kvalita
  • V súlade s RoHS
  • Certifikácia CE
  • 1-ročná záruka

Dokumenty k produktu

Dátový list

Technické špecifikácie a údaje o výkone

Používateľská príručka

Návod na inštaláciu a obsluhu

Top