LIT 2-24 - LIT 2-24 2804665 PHOENIX CONTACT Surge protection device
Na sklade Horúci produkt

LIT 2-24

LIT 2-24 2804665 PHOENIX CONTACT Surge protection device

$0.00 USD
4708 na sklade
Kľúčové špecifikácie
GTIN: 4046356428323
Orderkey: 2804665
(General): Ex iaD 20 T85 °C...T135 °C
Catalog page: Page 92 (C-6-2013)
Informácie o dodávateľovi
Produkty: 0
Zvyčajne sa odosiela do 2-3 pracovných dní
Zaručená kvalita
Rýchle doručenie
Technická podpora

Technické špecifikácie

Parameter Hodnota
GTIN 4046356428323
Orderkey 2804665
(General) Ex iaD 20 T85 °C...T135 °C
Catalog page Page 92 (C-6-2013)
Packing unit 10 pc
ATEX (General)  II 1 G Ex ia IIC T4...T6
IECEx (General) Ga Ex ia IIC T4...T6
Country of origin DE (Germany)
Capacity (General) ≤ 1.3 nF (per path)
Custom tariff number 85363010
Altitude (Dimensions) ≤ 2000 m (amsl (above mean sea level))
Rated current (General) 500 mA (40° C)
(Conformity / approvals) For details about hazardous substances go to tab “Downloads”, Category “Manufacturer's declaration”
Type (Ambient conditions) DIN rail module, one-piece
Color (Ambient conditions) anthracite grey RAL 7016
Depth (Key Commercial Data) 102.5 mm (incl. DIN rail 7.5 mm)
Width (Key Commercial Data) 6.2 mm
(Standards and Regulations) 500 mA (T6 / ≤ 40 °C)
Height (Key Commercial Data) 93.1 mm
Nominal voltage UN (General) 24 V DC
Residual current IPE (General) ≤ 2 µA
Resistance in series (General) 0 Ω
Degree of protection (Dimensions) IP20
IEC test classification (General) C1
Screw thread (Protective circuit) M3
Mounting type (Ambient conditions) DIN rail: 35 mm
China RoHS (Conformity / approvals) Environmentally Friendly Use Period = 50
Connection method (Connection data) DIN rail NS35
(Connection, equipotential bonding) IEC 60079-26 2006
Input attenuation aE, sym. (General) typ. 0.3 dB (2.4 MHz/50 Ω)
Max. required back-up fuse (General) 500 mA (T)
Weight per Piece (excluding packing) 52.000 g
Housing material (Ambient conditions) PBT
Response time tA(line-line) (General) ≤ 1 ns
Stripping length (Protective circuit) 8 mm
Connection method (Protective circuit) Screw connection
Response time tA(line-earth) (General) ≤ 100 ns
Tightening torque (Protective circuit) 0.8 Nm
Maximum continuous voltage UC (General) 36 V DC
Direction of action (Ambient conditions) Line-Line & Line-Earth Ground
Impulse durability (line-line) (General) C1 - 500 V / 250 A
Surge protection fault message (General) none
Impulse durability (line-earth) (General) C1 - 500 V / 250 A
Residual voltage at In(line-line) (General) ≤ 60 V
Ambient temperature (operation) (Dimensions) -40 °C ... 80 °C
Operating effective current ICat UC (General) ≤ 2 µA
max. input power Pi (Standards and Regulations) 635 mW
Conductor cross section AWG (Protective circuit) 24 ... 14
Voltage protection level Up(line-line) (General) ≤ 60 V (C1 - 500 V / 250 A)
Max. input current Ii (Standards and Regulations) 500 mA (T4 / ≤ 80°C)
Max. input voltage Ui (Standards and Regulations) 36 V DC
Voltage protection level Up(line-earth) (General) ≤ 650 V (C1 - 500 V / 250 A)
Conductor cross section solid (Protective circuit) 0.2 mm² ... 2.5 mm²
Total discharge current Itotal(8/20) µs (General) 10 kA
Ambient temperature (storage/transport) (Dimensions) -40 °C ... 80 °C
Conductor cross section flexible (Protective circuit) 0.2 mm² ... 2.5 mm²
Max. internal inductance Li (Standards and Regulations) < 1 µH
Maximum inner capacitance Ci (Standards and Regulations) typ. 1.3 nF
Flammability rating according to UL 94 (Ambient conditions) V-0
Alternating current carrying capacity (line-earth) (General) 5 A - 1 s
Cut-off frequency fg (3 dB), sym. in 50 Ohm system (General) typ. 7.7 MHz
Nominal discharge current In(8/20) µs (line-line) (General) 250 A
Standards/specifications (Connection, equipotential bonding) EN 61643-21 A2:2013
Cut-off frequency fg (3 dB), sym. in 150 Ohm system (General) typ. 2.5 MHz
Maximum inner time factor (Ri/Li) (Standards and Regulations) 10 µs
Nominal discharge current In(8/20) µs (line-earth) (General) 5 kA
Nominal pulse current Ian (10/1000) µs (line-line) (General) 50 A
Residual voltage with Ian (10/1000) µs (line-line) (General) ≤ 60 V
Nominal pulse current Ian (10/1000) µs (line-earth) (General) 50 A
Pulse discharge current Iimp(10/350) µs (line-earth) (General) 500 A
Output voltage limitation at 1 kV/µs (line-line) spike (General) ≤ 60 V
Output voltage limitation at 1 kV/µs (line-earth) spike (General) ≤ 650 V
Max. discharge current Imax(8/20) µs maximum (line-line) (General) 250 A
Max. discharge current Imax(8/20) µs maximum (line-earth) (General) 10 kA

Popis produktu

Surge protection on the module for one-piece symmetrical rail mounting, 6.2 mm wide, for two potential-free signal conductors. Tested according to the degrees of protection in the Ex zones: Ex ia IIC
Kľúčové vlastnosti
  • Priemyselná kvalita
  • V súlade s RoHS
  • Certifikácia CE
  • 1-ročná záruka

Dokumenty k produktu

Dátový list

Technické špecifikácie a údaje o výkone

Používateľská príručka

Návod na inštaláciu a obsluhu

Top