: Output stage cannot be controlled Error message in the diagnostic code (bus) and display via the LED ERR on the module
Note: Notes on operation Line protection for the network supply line, max. 20 A. Observe derating of the POWER-COMBICON connector
Type: modular
Depth: 109 mm
Informácie o dodávateľovi
Produkty: 0
Zvyčajne sa odosiela do 2-3 pracovných dní
Zaručená kvalita
Rýchle doručenie
Technická podpora

Technické špecifikácie

Parameter Hodnota
Output stage cannot be controlled Error message in the diagnostic code (bus) and display via the LED ERR on the module
Note Notes on operation Line protection for the network supply line, max. 20 A. Observe derating of the POWER-COMBICON connector
Type modular
Depth 109 mm
Width 63 mm
Height 224 mm
Filter time 0.2 ms
Current draw max. 50 mA
Typ produktu I/O component
Assembly note To safeguard sufficient ventilation, ensure that there is an installation clearance of a minimum of 50 cm both above and below.
ID code (hex) BF
Mounting type DIN rail mounting
ID code (dec.) 191
Operating mode Process data mode with one byte
Product family Inline
Supply voltage 7.5 V DC (via voltage jumper)
Register length 1 Byte
Number of inputs 1
Protection class I (IEC 61140, EN 61140, VDE 0140-1)
Connection method Inline data jumper
Length code (dec) 129
Length code (hex) 81
Mounting position Panel mounting on horizontal DIN rail
Power consumption max. 4.2 W (entire device)
Input address area 1 Byte
Transmission speed 500 kbps
Dimensional drawing
Number of positions 4
Output address area 1 Byte
Degree of protection IP20
Diagnostics messages Overcurrent Error message in the diagnostic code (bus) and display via the LED ERR on the module
Number of interfaces 2
Process data channel 8 bit
Supply voltage range 19.2 V DC ... 28.8 V DC (including all tolerances, including ripple)
Transmission physics Copper
Required parameter data 5 Byte
Air pressure (operation) 80 kPa ... 106 kPa (up to 2000 m above sea level)
Required configuration data 5 Byte
Ambient temperature (operation) -25 °C ... 55 °C
Air pressure (storage/transport) 70 kPa ... 106 kPa (up to 3000 m above sea level)
Permissible humidity (operation) 10 % ... 85 % (non-condensing)
Test voltage: Local bus/400 V level 1.2 kV AC, 50 Hz, 1 min.
Ambient temperature (storage/transport) -25 °C ... 85 °C
Permissible humidity (storage/transport) 10 % ... 85 % (non-condensing)
Test voltage: Local bus/Brake control switch 1.2 kV AC, 50 Hz, 1 min.
Test voltage: Supply voltage UL/ 400 V level 1.2 kV AC, 50 Hz, 1 min.
Test voltage: Supply voltage US/ 400 V level 1.2 kV AC, 50 Hz, 1 min.
Test voltage: Supply voltage UL/ brake control switch 1.2 kV AC, 50 Hz, 1 min.
Test voltage: Supply voltage US/ brake control switch 1.2 kV AC, 50 Hz, 1 min.

Popis produktu

Inline power terminals, electromechanical direct start controller, up to 3.7 kW / 400 V AC