HC-M-02-MOD-ST - HC-M-02-MOD-ST 1679346 PHOENIX CONTACT HEAVYCON contact insert module, male, 2-pos., axial screw connection
Na sklade Horúci produkt

HC-M-02-MOD-ST

HC-M-02-MOD-ST 1679346 PHOENIX CONTACT HEAVYCON contact insert module, male, 2-pos., axial screw connection

$0.00 USD
4329 na sklade
Kľúčové špecifikácie
: Note regarding axial connection technology:Only for stranded wires. The conductor cross sections stated refer to the geometric cross section of the cable used.Use of cables with a geometric cross section very different from that of the cable's nominal cross section should be checked before use.The wiring space of the axial screw method is designed for fine strand cables according to VDE 0295 class 5. Deviating cable structures (e.g. class 6 cables) should be checked before use.ConnectionBefore starting to connect, ensure that the tapered screw is turned back all the way (chamber is open). The cables must not be twisted. The cores should be slid to the limit stop in the contact chamber (until insulation touches contact). Hold cores in position and use socket wrench to tighten. The used core end should be cut off before connecting again. The connection screw may only be retightened once to prevent the strands from breaking. To prevent damage to the contact, the core / cable should be mechanically intercepted at an appropriate distance from the connection point (e.g. by using a plate cutout). DIN VDE 0100-520:2003-06 contains information on how to do this correctly.
Width: 34.2 mm
Height: 41.8 mm
Length: 14.6 mm
Informácie o dodávateľovi
Produkty: 0
Zvyčajne sa odosiela do 2-3 pracovných dní
Zaručená kvalita
Rýchle doručenie
Technická podpora

Technické špecifikácie

Parameter Hodnota
Note regarding axial connection technology:Only for stranded wires. The conductor cross sections stated refer to the geometric cross section of the cable used.Use of cables with a geometric cross section very different from that of the cable's nominal cross section should be checked before use.The wiring space of the axial screw method is designed for fine strand cables according to VDE 0295 class 5. Deviating cable structures (e.g. class 6 cables) should be checked before use.ConnectionBefore starting to connect, ensure that the tapered screw is turned back all the way (chamber is open). The cables must not be twisted. The cores should be slid to the limit stop in the contact chamber (until insulation touches contact). Hold cores in position and use socket wrench to tighten. The used core end should be cut off before connecting again. The connection screw may only be retightened once to prevent the strands from breaking. To prevent damage to the contact, the core / cable should be mechanically intercepted at an appropriate distance from the connection point (e.g. by using a plate cutout). DIN VDE 0100-520:2003-06 contains information on how to do this correctly.
Width 34.2 mm
Height 41.8 mm
Length 14.6 mm
Series HC-M-02
General For HEAVYCON housing type B6 to B48, HC-M-MHR... hinged retaining frame required
Application Power
Typ produktu Modular contact insert
Assembly note - Connection of the wires using a 2 mm Allen wrench.- Housing height ≥ 52 mm.- Axial screw connection only for flexible wires.- Plug-in connections may only be operated only when there is no load/voltage.
Rated current 40 A
Contact material Copper alloy
Hexagonal socket SW 2
Contact numbering 1 - 2
Tightening torque 1.5 Nm (2.5 mm² ... 4 mm²)
Connection profile 2
Degree of pollution 3
Dimensional drawing
Number of positions 2
Rated surge voltage 8 kV
Overvoltage category III
Connection technology Axial screw connection
Rated voltage (III/3) 1000 V
Number of module slots 1
Conductor cross section 2.5 mm² ... 8 mm² (The cross section specification refers to the geometric cross section of the cable used)
Contact carrier material PC
Contact surface material Ag
Insertion/withdrawal cycles ≥ 500
Connection cross section AWG 12 ... 10
Ambient temperature (operation) -40 °C ... 125 °C
Connection in acc. with standard IEC / EN
Flammability rating according to UL 94 V0
Stripping length of the individual wire 8 mm +1 mm (for 6 mm²)