Kľúčové špecifikácie
: SPD according to AS/NZS 1768 Cat. C3
Note: Max. single impulse: 100 kA (8/20 µs)
Type: DIN rail module, two-section, divisible
Depth: 74.5 mm
Informácie o dodávateľovi
Produkty: 0
Zvyčajne sa odosiela do 2-3 pracovných dní
Zaručená kvalita
Rýchle doručenie
Technická podpora

Technické špecifikácie

Parameter Hodnota
SPD according to AS/NZS 1768 Cat. C3
Note Max. single impulse: 100 kA (8/20 µs)
Type DIN rail module, two-section, divisible
Depth 74.5 mm
Width 71.2 mm
Height 95.2 mm
EN type T1 / T2
Altitude ≤ 2000 m (amsl)
SPD Type 2CA
Typ produktu Combination type
Screw thread M5
Mounting type DIN rail: 35 mm
Material group I
Product family SEC Family
Connection name Remote fault indicator contact
Nominal voltage 240 V AC
Open side panel No
Article revision 08
Horizontal pitch 4 Div.
Housing material PA 6.6-FR 20 % GF
Pollution degree 2
Response time tA ≤ 100 ns
Stripping length 18 mm
Connection method Screw terminal blocks
Nominal frequency 50/60 Hz
Operating current 10 mA AC ... 1 A AC
Operating voltage 12 V AC ... 250 V AC
Shock (operation) 30g (Half-sine / 11 ms / 3x ±X, ±Y, ±Z)
Tightening torque 4.5 Nm
Mode of protection L-PEN
Nominal voltage UN 240/415 V AC (TN-C)
Switching function Changeover contact
TOV behavior at UT 415 V AC (5 s / withstand mode)
Dimensional drawing
Direction of action 2L-PEN
Insulating material PA6.6-FR 20% GF
Number of positions 2
AC operating current 1 A AC
Color (Base element) gray (RAL 7042)
Degree of protection IP20 (only when all terminal points are used)
Nominal frequency fN 50 Hz (60 Hz)
Overvoltage category III
CTI value of material 600
Rated load current IL 125 A (< 55 °C)
Residual voltage Ures ≤ 1.5 kV (at In)
Vibration (operation) 5g (5 - 500 Hz/2.5 h/X, Y, Z)
Color (Male connector) light gray (RAL 7035)
IEC power supply system TN-C
IEC test classification I / II
Standards/specifications IEC 61643-11
Power distribution system Delta
Conductor cross section AWG 13 ... 2
Voltage protection level Up ≤ 1.5 kV
Nominal discharge current In 20 kA
Conductor cross section rigid 2.5 mm² ... 35 mm²
Maximum continuous voltage UC 350 V AC
Surge protection fault message Optical, remote indicator contact
Ambient temperature (operation) -40 °C ... 80 °C
Conductor cross section flexible 2.5 mm² ... 35 mm²
Permissible humidity (operation) 5 % ... 95 %
Short-circuit current rating ISCCR 50 kA
Follow current interrupt rating Ifi 50 kA
Max. backup fuse with branch wiring 315 A (gG)
Short-circuit current rating (SCCR) 50 kA
Voltage protection rating VPR (L-G) 1500 V
Voltage protection rating VPR (L-L) 2000 V
Flammability rating according to UL 94 V-0
Nominal discharge current In(8/20) µs 25 kA
Ambient temperature (storage/transport) -40 °C ... 80 °C
Maximum discharge current Imax(8/20) µs 50 kA
Max. backup fuse with V-type through wiring 125 A (gG)
Total discharge current Itotal(10/350) µs 50 kA
Impulse discharge current (10/350) µs, charge 12.5 As
Maximum continuous operating voltage MCOV (L-G) 350 V AC
Maximum continuous operating voltage MCOV (L-L) 700 V AC
Front of wave sparkover voltage at 6 kV (1.2/50) µs ≤ 1.5 kV
Impulse discharge current (10/350) µs, peak value limp 25 kA
Impulse discharge current (10/350) µs, specific energy 160 kJ/Ω

Popis produktu

Plug-in lightning current arrester, according to type 1/class I, for two-phase power grids with PE and N routing combined in one conductor (L1, L2, PEN).
Kľúčové vlastnosti
  • Priemyselná kvalita
  • V súlade s RoHS
  • Certifikácia CE
  • 1-ročná záruka

Dokumenty k produktu

Dátový list

Technické špecifikácie a údaje o výkone

Používateľská príručka

Návod na inštaláciu a obsluhu

Top