Čas služby: pondelok až piatok 9:00-18:00
FLT-SEC-H-T1-3C-264/25-FM - FLT-SEC-H-T1-3C-264/25-FM 2905871 PHOENIX CONTACT Combination type 1/2 protective device
Na sklade Horúci produkt

FLT-SEC-H-T1-3C-264/25-FM

FLT-SEC-H-T1-3C-264/25-FM 2905871 PHOENIX CONTACT Combination type 1/2 protective device

$0.00 USD
3734 na sklade
Kľúčové špecifikácie
GTIN: 4055626003825
Orderkey: 2905871
(General): 460 V AC (120 min / withstand mode)
Catalog page: Page 28 (C-4-2017)
Informácie o dodávateľovi
Produkty: 0
Zvyčajne sa odosiela do 2-3 pracovných dní
Zaručená kvalita
Rýchle doručenie
Technická podpora

Technické špecifikácie

Parameter Hodnota
GTIN 4055626003825
Orderkey 2905871
(General) 460 V AC (120 min / withstand mode)
Catalog page Page 28 (C-4-2017)
Packing unit 1 pc
Country of origin DE (Germany)
(Connection data) EN 61643-11 2012
Custom tariff number 85363030
(Ambient conditions) PBT-FR
Altitude (Dimensions) ≤ 4000 m (amsl (above mean sea level))
Type (Ambient conditions) DIN rail module, two-section, divisible
Color (Ambient conditions) light grey RAL 7035
Response time tA (General) ≤ 100 ns
Depth (Key Commercial Data) 74.5 mm (incl. DIN rail 7.5 mm)
Width (Key Commercial Data) 106.8 mm
(Additional technical data) 1 A DC (30 V DC)
(Standards and Regulations) For details about hazardous substances go to tab “Downloads”, Category “Manufacturer's declaration”
EN type (Ambient conditions) T1 / T2
Height (Key Commercial Data) 167 mm
Nominal voltage UN (General) 240/415 V AC (TN-C)
TOV behavior at UT (General) 415 V AC (5 s / withstand mode)
Nominal frequency fN (General) 50 Hz (60 Hz)
Residual voltage Ures (General) ≤ 1.5 kV (at In)
Degree of protection (Dimensions) IP20 (only when all terminal points are used)
Mounting type (Ambient conditions) DIN rail: 35 mm
Weight per Piece (excluding packing) 1,792.000 g
Housing material (Ambient conditions) PA 6.6-FR 20% GF
Voltage protection level Up (General) ≤ 1.5 kV
China RoHS (Standards and Regulations) Environmentally Friendly Use Period = 50
Horizontal pitch (Key Commercial Data) 6 Div.
REACh SVHC (Standards and Regulations) Lead 7439-92-1
Maximum continuous voltage UC (General) 264 V AC
Mode of protection (Ambient conditions) L-PEN
Standards/regulations (Connection data) IEC 61643-11 2011
Degree of pollution (Ambient conditions) 2
Number of positions (Ambient conditions) 3
Screw thread (Additional technical data) M2
Screw thread (Indicator/remote signaling) M5
Ambient temperature (operation) (Dimensions) -40 °C ... 80 °C
IEC power supply system (Ambient conditions) TN-C
IEC test classification (Ambient conditions) I / II
Short-circuit current rating ISCCR (General) 50 kA
Stripping length (Additional technical data) 7 mm
Connection method (Additional technical data) Plug-in/screw connection via COMBICON
Follow current interrupt rating Ifi (General) 50 kA
Operating current (Additional technical data) 10 mA AC ... 1 A AC
Operating voltage (Additional technical data) 12 V AC ... 250 V AC
Permissible humidity (operation) (Dimensions) 5 % ... 95 %
Stripping length (Indicator/remote signaling) 18 mm
Tightening torque (Additional technical data) 0.25 Nm
Connection method (Indicator/remote signaling) Fork-type cable lug
Switching function (Additional technical data) PDT contact
Tightening torque (Indicator/remote signaling) 4.5 Nm
Nominal discharge current In(8/20) µs (General) 25 kA
Maximum continuous voltage UC (Protective circuit) 275 V AC
Maximum discharge current Imax(8/20) µs (General) 50 kA
Surge protection fault message (Ambient conditions) Optical, remote indicator contact
Ambient temperature (storage/transport) (Dimensions) -40 °C ... 80 °C
Total discharge current Itotal(10/350) µs (General) 75 kA
Conductor cross section AWG (Additional technical data) 28 ... 16
Short-circuit current rating ISCCR (Protective circuit) 100 kA
Conductor cross section AWG (Indicator/remote signaling) 13 ... 2
Follow current interrupt rating Ifi (Protective circuit) 100 kA
Impulse discharge current (10/350) µs, charge (General) 12.5 As
Conductor cross section solid (Additional technical data) 0.14 mm² ... 1.5 mm²
Conductor cross section solid (Indicator/remote signaling) 2.5 mm² ... 35 mm²
Flammability rating according to UL 94 (Ambient conditions) V-0
Conductor cross section flexible (Additional technical data) 0.14 mm² ... 1.5 mm²
Conductor cross section flexible (Indicator/remote signaling) 1.5 mm² ... 16 mm²
Distance between live and grounded parts (Ambient conditions) 1 mm
Maximum discharge current Imax(8/20) µs (Protective circuit) 100 kA (AS NZS 1768:2007)
Front of wave sparkover voltage at 6 kV (1.2/50) µs (General) ≤ 1.5 kV
Impulse discharge current (10/350) µs, peak value limp (General) 25 kA
Impulse discharge current (10/350) µs, specific energy (General) 160 kJ/Ω

Popis produktu

Plug-in lightning current arrester, according to type 1/class I, with fuse resistant to momentary overcurrents, for three-phase power supply networks with PE and N placed in combination on one conduct
Kľúčové vlastnosti
  • Priemyselná kvalita
  • V súlade s RoHS
  • Certifikácia CE
  • 1-ročná záruka

Dokumenty k produktu

Dátový list

Technické špecifikácie a údaje o výkone

Používateľská príručka

Návod na inštaláciu a obsluhu

Top