Kľúčové špecifikácie
Item (Accessories): Load power supply voltage range
Weight (Accessories): Approx. 200 g (including terminal cover)
Indications (Accessories): LED indicators
Alarm output (Accessories): NPN open collector, one outputMax. applicable voltage: 30 VDCMax. load current: 50 mAResidual voltage: 1.5 V max.Leakage current: 0.4 mA max.
Informácie o dodávateľovi
OMRON
OMRON
Produkty: 41472
Zvyčajne sa odosiela do 2-3 pracovných dní
Zaručená kvalita
Rýchle doručenie
Technická podpora

Technické špecifikácie

Parameter Hodnota
Item (Accessories) Load power supply voltage range
Weight (Accessories) Approx. 200 g (including terminal cover)
Indications (Accessories) LED indicators
Alarm output (Accessories) NPN open collector, one outputMax. applicable voltage: 30 VDCMax. load current: 50 mAResidual voltage: 1.5 V max.Leakage current: 0.4 mA max.
Name (Ordering information) Hole diameter
100 to 240 VAC (Accessories) 400 to 480 VAC
Trigger output (Accessories) One voltage output for each channel, 12 VDC ±15%, max. load current: 21 mA(with built-in short-circuit protection circuit)
Shock resistance (Accessories) 300 m/s2three times each in six directions along three axes
Memory protection (Accessories) EEPROM (non-volatile memory) (number of writes: 100,000)
Power consumption (Accessories) 16 VA max.
12.0 dia. (Ordering information) E54-CT3
Approved standards (Accessories) UL508 (Listing), CSA22.2 No. 14EN50178EN61000-6-4 (EN55011: 1998, A1: 1999 Class A, Group 1)EN61000-6-2: 2001
Dielectric strength (Accessories) 2,000 VAC, 50/60 Hz for 1 min between primary and secondary
Storage temperature (Accessories) -25 to 65°C (with no icing or condensation)
Degree of protection (Accessories) IP20
Power supply voltage (Accessories) 100 to 240 VAC (50/60 Hz)
Size in mm (H×W×D) (Accessories) 76×45×111
Vibration resistance (Accessories) Vibration frequency: 10 to 55 Hz, acceleration: 50 m/s2in X, Y, and Z directions
Insulation resistance (Accessories) 100 MΩ min. (at 500 VDC) between primary and secondary
Operating voltage range (Accessories) 85 to 264 VAC
Installation environment (Accessories) Overvoltage category III, pollution degree 2 (according to IEC 60664-1)
Current transformer input (Accessories) Single-phase AC, 0 to 50 A (primary current of CT)
Load power supply voltage (Accessories) 100 to 240 VAC
Ambient operating humidity (Accessories) 25 to 85%
Manipulated variable input (Accessories) 0.0 to 100.0% (via RS-485 communications)
Current indication accuracy (Accessories) ±3 A (for models with heater burnout detection)
Ambient operating temperature (Accessories) -10 to 55°C (with no icing or condensation)
Load power supply voltage range (Accessories) 75 to 264 VAC
Current transformer (CT) (Ordering information) 5.8 dia.
8 (Multi-channel power controller for smarter SSR usage) Not supported
Name (Multi-channel power controller for smarter SSR usage) Number of control channels
400 to 480 VAC (Multi-channel power controller for smarter SSR usage) G3ZA-8A403-FLK-UTU
Multi-channel power controller (Multi-channel power controller for smarter SSR usage) 4

Popis produktu

Current transformer for heater burnout detection (12mm dia)
Kľúčové vlastnosti
  • Priemyselná kvalita
  • V súlade s RoHS
  • Certifikácia CE
  • 1-ročná záruka

Technické detaily

The G3ZA receives manipulated variables generated by control loops or manual settings via a simple-to-wire RS-485. It regulates the heater power with high precision by driving up to eight standard SSRs. Moreover, the offset control reduces peak power in the supply net.

Dokumenty k produktu

Dátový list

Technické špecifikácie a údaje o výkone

Používateľská príručka

Návod na inštaláciu a obsluhu

Top