Čas služby: pondelok až piatok 9:00-18:00
CT 10-18FS+F/PE-24 - CT 10-18FS+F/PE-24 2807926 PHOENIX CONTACT Surge protection plug
Na sklade Horúci produkt

CT 10-18FS+F/PE-24

CT 10-18FS+F/PE-24 2807926 PHOENIX CONTACT Surge protection plug

$0.00 USD
4279 na sklade
Kľúčové špecifikácie
GTIN: 4017918075408
Note: Made to Order (non-returnable)
Orderkey: 2807926
(General): D1 - 2.5 kA
Informácie o dodávateľovi
Produkty: 0
Zvyčajne sa odosiela do 2-3 pracovných dní
Zaručená kvalita
Rýchle doručenie
Technická podpora

Technické špecifikácie

Parameter Hodnota
GTIN 4017918075408
Note Made to Order (non-returnable)
Orderkey 2807926
(General) D1 - 2.5 kA
Catalog page Page 107 (C-6-2013)
Packing unit 1 pc
Country of origin DE (Germany)
(Connection data) EN 61643-21 2001 + A1:2009 + A2:2013
Custom tariff number 85363010
Altitude (Dimensions) ≤ 2000 mm (amsl (above mean sea level))
Rated current (General) 1.5 A AC (75 °C)
Type (Ambient conditions) LSA-PLUS module
Color (Ambient conditions) jet black RAL 9005
Depth (Key Commercial Data) 68.5 mm
Width (Key Commercial Data) 111 mm
(Standards and Regulations) No hazardous substances above threshold values
Height (Key Commercial Data) 22 mm
Nominal voltage UN (General) 24 V DC
Residual current IPE (General) ≤ 1 µA (19x)
Degree of protection (Dimensions) IP20
IEC test classification (General) C1
Mounting type (Ambient conditions) On CT-TERMIBLOCK and LSA-PLUS disconnect strip
Weight per Piece (excluding packing) 106.510 g
Housing material (Ambient conditions) PBT
Input attenuation aE, asym. (General) typ. 0.1 dB (≤ 2 MHz / 50 Ω)
Capacity (line-signalground) (General) typ. 1.1 nF (1 MHz)
China RoHS (Standards and Regulations) Environmentally friendly use period: unlimited = EFUP-e
Connection method (Protective circuit) can be plugged into COMTRAB-TERMIBLOCK and LSA-PLUS disconnect and switching strips
Response time tA(line-earth) (General) ≤ 100 ns
Maximum continuous voltage UC (General) 40 V DC
Direction of action (Ambient conditions) Line-Signal Ground/Shield & Signal Ground/Shield-Earth Ground
Surge protection fault message (General) none
Connection method IN (Protective circuit) COMTRAB plug-in system
Impulse durability (line-earth) (General) C2 - 10 kV/5 kA
Connection method OUT (Protective circuit) COMTRAB plug-in system
Standards/specifications (Connection data) IEC 61643-21 2000 + corrigendum 2001 + A1:2008, modified + A2:2012
Ambient temperature (operation) (Dimensions) -25 °C ... 75 °C
Residual voltage at In(line-earth) (General) ≤ 30 V
Operating effective current ICat UC (General) ≤ 5 µA (18x)
Response time tA (line-signalground) (General) ≤ 1 ns
Impulse durability (line-signalground) (General) C3 - 23 A
Impulse durability (signalground-earth) (General) D1 - 2.5 kA
Total discharge current Itotal(8/20) µs (General) 10 kA
Residual voltage at In(line-signalground) (General) ≤ 85 V
Flammability rating according to UL 94 (Ambient conditions) V-0
Nominal discharge current In(8/20) µs (line-line) (General) 119 A (per path)
Nominal discharge current In(8/20) µs (line-earth) (General) 5 kA (per path)
Pulse discharge current Iimp(10/350) µs (line-earth) (General) 2.5 kA
Output voltage limitation at 1 kV/µs (line-earth) spike (General) ≤ 650 V
Cut-off frequency fg (3 dB), asym. (GND) in 50 Ohm system (General) typ. 10 MHz
Max. discharge current Imax(8/20) µs maximum (line-line) (General) 119 A (per path)
Standards for cearances and creepage distances (Ambient conditions) VDE 0110-1
Cut-off frequency fg (3 dB), asym. (GND) in 150 Ohm system (General) typ. 2.5 MHz
Cut-off frequency fg (3 dB), asym. (GND) in 600 Ohm system (General) typ. 650 kHz
Max. discharge current Imax(8/20) µs maximum (line-earth) (General) 5 kA (per path)
Nominal discharge current In(8/20) µs (signalground-earth) (General) 5 kA (per path)
Nominal pulse current Ian (10/1000) µs (line-signalground) (General) 23 A
Residual voltage with Ian (10/1000) µs (line-signalground) (General) ≤ 65 V
Pulse discharge current Iimp(10/350) µs (signalground-earth) (General) 2.5 kA
Output voltage limitation at 1 kV/µs (line-signalground) spike (General) ≤ 70 V
Output voltage limitation at 1 kV/µs (line-signalground) static (General) ≤ 60 V
Arrester can be tested with CHECKMASTER from software version: (Ambient conditions) From SW rev. 1.00

Popis produktu

LSA-PLUS (COMTRAB CT 10) connector with coarse/fine surge protection for 18 signal lines - GND and coarse GND protection - PE. Nominal voltage: 24 V DC. Version: 10 two-wire circuits
Kľúčové vlastnosti
  • Priemyselná kvalita
  • V súlade s RoHS
  • Certifikácia CE
  • 1-ročná záruka

Dokumenty k produktu

Dátový list

Technické špecifikácie a údaje o výkone

Používateľská príručka

Návod na inštaláciu a obsluhu

Top