Čas služby: pondelok až piatok 9:00-18:00
5SV4442-0 - 5SV4442-0 SIEMENS Residual current operated circuit breaker, 4-pole, Type AC, In: 25 A, 100 mA, Un AC: 400 V
Na sklade Horúci produkt

5SV4442-0

5SV4442-0 SIEMENS Residual current operated circuit breaker, 4-pole, Type AC, In: 25 A, 100 mA, Un AC: 400 V

$0.00 USD
4577 na sklade
Kľúčové špecifikácie
: Confirmation
EAN: 4001869427966
EMC: Declaration of Conformity
UPC: Not available
Informácie o dodávateľovi
SIEMENS
SIEMENS
Produkty: 367174
Zvyčajne sa odosiela do 2-3 pracovných dní
Zaručená kvalita
Rýchle doručenie
Technická podpora

Technické špecifikácie

Parameter Hodnota
Confirmation
EAN 4001869427966
EMC Declaration of Conformity
UPC Not available
depth 70 mm
width 72 mm
height 90 mm
Railway Dangerous Good
Group Code P310
net weight 350 g
● maximum 2.1 W
● minimum 0.75 mm²
Confirmation Vibration and Shock
Date5/6/2022
Metal Factor L-A-----
Product Group 5510
Product class A: Standard product which is a stock item could be returned within the returns guidelines/period.
Quantity Unit 1 Piece
Commodity Code 85362010
Product family Not available
power loss [W]
Net Weight (kg) 0,305 Kg
number of poles 4
fastening method DIN rail (REG)
Country of origin Germany
mounting position any
LKZ_FDB/ CatalogID LV10.1
Packaging Quantity 1
installation depth 70 mm
product brand name SENTRON
Packaging Dimension 97,00 x 78,00 x 85,00
Product Description Residual current operated circuit breaker, 4-pole, Type AC, In: 25 A, 100 mA, Un AC: 400 V
operational current
product designation RCCB
protection class IP IP20, if the distribution board is installed, with connected conductors
Frequency (EF005455) 50 Hz
overvoltage category III
design of the product Instantaneous
residual current type AC
I2t value / permissible 58 000 A²·s
Product Lifecycle (PLM) PM300:Active Product
● at AC / rated value 25 A
● maximum permissible 75 °C
● minimum permissible -40 °C
Rated current (EF000227) 25
Rated voltage (EF000228) 400
Built-in depth (EF000218) 70.0
Export Control Regulations ECCN : N / AL : N
Mounting method (EF000003) DIN rail
Number of poles (EF001391) 4
switching capacity current
Pollution degree (EF002570) -
Standard lead time ex-works 70 Day/Days
Surcharge for Raw Materials None
● at 40 °C / rated value 25 A
● at 45 °C / rated value 25 A
● at 50 °C / rated value 25 A
● at 55 °C / rated value 25 A
● at 60 °C / rated value 25 A
● at 65 °C / rated value 23.3 A
● at 70 °C / rated value 17.6 A
Package size unit of measure MM
short-circuit current rating 10 kA
number of modular width units 4
Rated fault current (EF002358) 0.1
product feature / silicon-free Yes
Leakage current type (EF002560) AC
Selective protection (EF002561) false
position / of power supply cord top or bottom
Surge current capacity (EF002564) -
let-through current / permissible 5 200 A
With interlocking device (EF007385) true
Degree of protection (IP) (EF005474) IP20
ambient temperature / during storage
tripping fault current / rated value 100 mA
Article Number (Market Facing Number) 5SV4442-0
Rated insulation voltage Ui (EF001366) -
Short-time delayed tripping (EF003604) false
WEEE (2012/19/EU) Take-Back Obligation Yes
ambient temperature / during operation
switching function / short-term delayed No
Additional equipment possible (EF008148) true
value range / of the operating frequency 50 Hz
● according to IEC 61008-1 / rated value 0.8 kA
connectable conductor cross-section / solid
value range / of the supply voltage / at AC 230/400 V
tightening torque / with screw-type terminals
value range / of the supply voltage frequency 50 Hz
Width in number of modular spacings (EF002950) 4
connectable conductor cross-section / stranded
Ambient temperature during operating (EF007515) ['-25', '45']
Rated impulse withstand voltage Uimp (EF011980) -
Short-circuit breaking capacity (Icw) (EF002562) 10.0
supply voltage / for testing equipment / minimum 100 V
Region Specific PriceGroup / Headquarter Price Group 194 / 1AI
mechanical service life (switching cycles) / typical 10 000
size of installation devices / according to DIN 43880 1
product extension / installable / supplementary devices Yes
Connectable conductor cross section solid-core (EF007337) ['0.75', '35.0']
Connectable conductor cross section multi-wired (EF007343) ['0.75', '35.0']
short-circuit current / of series fuse / maximum permissible 80 A
Compliance with the substance restrictions according to RoHS directive Since: 01.06.2006
REACH Art. 33 Duty to inform according to the current list of candidates Lead CAS-No. 7439-92-1 > 0, 1 % (w / w)Information obligation imposed by Article 33, REACH Regulation: This product includes one or several articles in which the following substance of the candidate list is contained in concentrations higher than 0,1% weight by weight (w/w):LeadBased on the information currently available, we assume that these substances do not pose any risk if the articles are used as intended (including disposal). Please also refer to product documentation.Lead monoxide (lead ... CAS-No. 1317-36-8 > 0, 1 % (w / w)Information obligation imposed by Article 33, REACH Regulation: This product includes one or several articles in which the following substance of the candidate list is contained in concentrations higher than 0,1% weight by weight (w/w):Lead monoxide (lead oxide)Based on the information currently available, we assume that these substances do not pose any risk if the articles are used as intended (including disposal). Please also refer to product documentation.
● for rated value of the current / at AC / in hot operating state / per pole 0.7 W
number of test cycles / for environmental testing / according to IEC 60068-2-30 28
General Product ApprovalConfirmationMiscellaneousEMCDeclaration of ConformityTest CertificatesotherUK Declaration of ConformityMiscellaneousEnvironmental ConfirmationsMiscellaneousRailwayDangerous GoodConfirmationVibration and ShockTransport Information General Product Approval

Popis produktu

More details
Kľúčové vlastnosti
  • Priemyselná kvalita
  • V súlade s RoHS
  • Certifikácia CE
  • 1-ročná záruka

Dokumenty k produktu

Dátový list

Technické špecifikácie a údaje o výkone

Používateľská príručka

Návod na inštaláciu a obsluhu

Top