Čas služby: pondelok až piatok 9:00-18:00
3LD2866-1GP53 - 3LD2866-1GP53 SIEMENS SENTRON, Switch disconnector 3LD, emergency switching-off switch, 3- pole, Iu: 125 A, ..
Na sklade Horúci produkt

3LD2866-1GP53

3LD2866-1GP53 SIEMENS SENTRON, Switch disconnector 3LD, emergency switching-off switch, 3- pole, Iu: 125 A, ..

$0.00 USD
4383 na sklade
Kľúčové špecifikácie
: Confirmation
EAN: 4011209524439
UPC: Not available
ETIM: 5
Informácie o dodávateľovi
SIEMENS
SIEMENS
Produkty: 367174
Zvyčajne sa odosiela do 2-3 pracovných dní
Zaručená kvalita
Rýchle doručenie
Technická podpora

Technické špecifikácie

Parameter Hodnota
Confirmation
EAN 4011209524439
UPC Not available
ETIM 5
depth 181 mm
width 212 mm
UNSPSC 14
eClass 6
height 302 mm
● solid 1x (4...50mm²)
Group Code P360
net weight 1 813 g
● maximum 1
● minimum 12
Date5/4/2022
Metal Factor LAO-----
● stranded 1x (4...50mm²)
Product Group 5887
Product class A: Standard product which is a stock item could be returned within the returns guidelines/period.
Quantity Unit 1 Piece
Commodity Code 85365080
Product family Basic Devices
power loss [W]
type of device fixed mounting
type of switch Molded-plastic enclosure for metric threaded joint
Net Weight (kg) 1,819 Kg
number of poles 3
operating power
product feature
● main switch Yes
● motor drive No
design of handle rotary operating mechanism, red/yellow
fastening method Complete unit in enclosure
Country of origin Germany
● rail mounting No
● safety switch Yes
LKZ_FDB/ CatalogID LV10.1
Packaging Quantity 1
product brand name SENTRON
Packaging Dimension 229,00 x 323,00 x 204,00
Product Description SENTRON, Switch disconnector 3LD, emergency switching-off switch, 3- pole, Iu: 125 A, operating power / at AC-23 A 400 V: 45 kW, Molded plastic encapsulation for metric cable gland, 1 NC, 1 NO, rotary operating mechanism, red/yellow
operational current
product designation 3LD Switch disconnector
protection class IP IP65
suitability for use
● voltage trigger No
design of the product EMERGENCY-STOP switch
number of poles / note N
Product Lifecycle (PLM) PM300:Active Product
design of the fuse link
● at AC / rated value 125 A
● switch disconnector Yes
General Product Approval Declaration of Conformity
Interlockable (EF006281) true
● EMERGENCY OFF switch Yes
● 4-hole front mounting No
● at AC-23 A / at 690 V 6 000
Export Control Regulations AL : N / ECCN : N
Number of poles (EF001391) 3
● for auxiliary contacts connection terminals
Environmental Confirmations Miscellaneous
Standard lead time ex-works 80 Day/Days
Surcharge for Raw Materials None
size of switch disconnector 4
● at 40 °C / rated value 125 A
● at 45 °C / rated value 125 A
● at 50 °C / rated value 125 A
● at 55 °C / rated value 125 A
● per conductor / typical 12 W
Package size unit of measure MM
product extension / optional
● for main current circuit box terminal
Number of switches (EF005586) 1
operating frequency / maximum 50 1/h
type of electrical connection
● maintenance/repair switch Yes
Device construction (EF008240) Built-in device fixed built-in technique
type of fuse / according to UL RK5
Motor drive optional (EF007386) false
design of the actuating element Short rotary knob
color / of the actuating element red
degree of protection NEMA rating 1, 4X, 12
insulation voltage / rated value 690 V
Colour control element (EF007167) Red
Motor drive integrated (EF006697) false
Version as main switch (EF006981) true
number of bracket locks / maximum 3
operational current / rated value 125 A
Rated operating voltage (EF001435) -
Type of control element (EF006976) Short thumb-grip
protection class IP / on the front IP65
Switching power at 400 V (EF009166) -
Version as safety switch (EF006985) true
Voltage release optional (EF007491) false
● can be locked into OFF position Yes
● at AC-3 / at 240 V / rated value 22 kW
● at AC-3 / at 400 V / rated value 37 kW
● at AC-3 / at 690 V / rated value 30 kW
Article Number (Market Facing Number) 3LD2866-1GP53
Rated permanent current Iu (EF001389) 125.0
● at AC-21 / at 690 V / rated value 125 A
Degree of protection (NEMA) (EF011959) -
Suitable for floor mounting (EF007243) FALSE
Version as reversing switch (EF009408) false
WEEE (2012/19/EU) Take-Back Obligation Yes
ambient temperature / during operation
surge voltage resistance / rated value 6 kV
electrical endurance (switching cycles)
● at 690 V / by gG fuse / rated value 20 kA
● at AC-21 A / at 240 V / rated value 125 A
● at AC-21 A / at 440 V / rated value 125 A
● at AC-23 A / at 240 V / rated value 22 kW
● at AC-23 A / at 400 V / rated value 80 A
● at AC-23 A / at 440 V / rated value 45 kW
● at AC-23 A / at 690 V / rated value 37 kW
let-through current / with closed switch
● front mounting with central attachment Yes
type of the driving mechanism / motor drive No
Max. rated operation voltage Ue AC (EF007355) 690
Suitable for front mounting 4-hole (EF007247) false
Suitable for front mounting centre (EF007248) true
Suitable for intermediate mounting (EF007264) false
ambient temperature / during storage / minimum -25 °C
number of CO contacts / for auxiliary contacts 0
number of NC contacts / for auxiliary contacts 1
number of NO contacts / for auxiliary contacts 1
● finely stranded / with core end processing 1x (4...35mm²)
Rated operation power at AC-3, 400 V (EF001364) 37.0
hasp thickness / of the bracket locks / maximum 8 mm
hasp thickness / of the bracket locks / minimum 4 mm
Degree of protection (IP), front side (EF003118) IP65
Rated operation power at AC-23, 400 V (EF007027) 0.045
Rated short-time withstand current lcw (EF007050) 2.0
Version as emergency stop installation (EF006959) true
Version as maintenance-/service switch (EF006986) true
Rated permanent current at AC-21, 400 V (EF009165) 125
Rated permanent current at AC-23, 400 V (EF011777) -
Region Specific PriceGroup / Headquarter Price Group 12R / 1CL
mechanical service life (switching cycles) / typical 100 000
operational current / of upstream fuse / rated value 125 A
Conditioned rated short-circuit current Iq (EF001444) -
Suitable for distribution board installation (EF007262) false
Type of electrical connection of main circuit (EF006819) Frame clamp
● at 440 V / for combination switch + gG fuse / maximum 10 kA
insulation voltage / of the auxiliary switch / rated value 500 V
continuous current / of the auxiliary contact / rated value 10 A
operating voltage / of auxiliary contacts / at AC / maximum 500 V
Number of auxiliary contacts as change-over contact (EF003531) 0
● for short-circuit protection of the main circuit / required fuse gL/gG: 125 A
Number of auxiliary contacts as normally open contact (EF001376) 1
display version / for switch position indicator manual operation 1 ON - 0 OFF
AWG number / as coded connectable conductor cross section / solid
Number of auxiliary contacts as normally closed contact (EF001377) 1
conditional short-circuit current / with line-side fuse protection
type of connectable conductor cross-sections / for copper conductor
● for short-circuit protection of the auxiliary switch / required fuse gL/gG: 10 A
continuous current / of upstream fuse / according to UL / rated value 200 A
type of connectable conductor cross-sections / for auxiliary contacts
● at 690 V / for combination switch + gG fuse / maximum permissible 10 kA
Compliance with the substance restrictions according to RoHS directive Given
REACH Art. 33 Duty to inform according to the current list of candidates Reach InformationThere is currently no information on SVHC (Substances of Very High Concern http://echa.europa.eu/web/guest/candidate-list-table) from the supply chain and our established procedures for screening our products for Substances of Very High Concern.We compare our products regularly with the information of the upstream users with regard to the substances indicated in the candidate list in accordance with the requirements of the REACH regulation. As soon as we have new findings, our information will be updated accordingly.
operational current / at AC / according to UL 508/UL 60947-4-1 / rated value 125 A
● for rated value of the current / at AC / in hot operating state / per pole 12 W
number of connectable CO contacts / for auxiliary contacts / attachable / maximum 0
number of connectable NC contacts / for auxiliary contacts / attachable / maximum 2
number of connectable NO contacts / for auxiliary contacts / attachable / maximum 3
short-time withstand current (SCCR) / at 600 V / according to UL 508/UL 60947-4-1 10 kA
active power [hp] / at AC / at 480 V / according to UL 508/UL 60947-4-1 / rated value 75
active power [hp] / at AC / at 600 V / according to UL 508/UL 60947-4-1 / rated value 100
I2t value / with closed switch / at 690 V / for combination switch + gG fuse / maximum 104 kA2.s
operating voltage / at AC / at 50/60 Hz / according to UL 508/UL 60947-4-1 / rated value 600 V
let-through I2t value / with closed switch / at 440 V / for combination switch + gG fuse / maximum 104 kA2.s
General Product ApprovalConfirmationMiscellaneousGeneral Product ApprovalDeclaration of ConformityTest CertificatesMarine / ShippingUK Declaration of ConformityMiscellaneousSpecial Test CertificateotherEnvironmental ConfirmationsMiscellaneous General Product Approval

Popis produktu

More details
Kľúčové vlastnosti
  • Priemyselná kvalita
  • V súlade s RoHS
  • Certifikácia CE
  • 1-ročná záruka

Dokumenty k produktu

Dátový list

Technické špecifikácie a údaje o výkone

Používateľská príručka

Návod na inštaláciu a obsluhu

Top